- 20:30 功能 #3162 (已解决): TSR_010_spi communication error 软件代码变更
- 20:29 功能 #3161 (新建): TSR_010_spi communication error 文档及架构图变更
- 20:27 功能 #3160 (已解决): TSR_009_KL30 under voltage(<9V)软件代码变更
- 20:26 功能 #3159 (新建): TSR_009_KL30 under voltage(<9V)文档及架构图变更
- 20:23 功能 #3158 (已解决): TSR_008_KL30 over voltage(>16V)软件代码变更
- 20:22 功能 #3157 (新建): TSR_008_KL30 over voltage(>16V)文档及架构图变更
- 20:17 功能 #3156 (已解决): TSR_007_LDM temperature fault代码软件变更
- 20:16 功能 #3155 (新建): TSR_007_LDM temperature fault文档及架构图变更
- 20:14 功能 #3154 (已解决): TSR_006_Over-voltage/under-voltage fault软件代码变更
- 已经按Software Safety Specification需求完成
- 20:13 功能 #3153 (新建): TSR_006_Over-voltage/under-voltage fault文档及架构图变更
- 20:10 功能 #3152 (已解决): TSR_005_LED_open软件代码变更
- 20:09 功能 #3151 (新建): TSR_005_LED_open文档及架构图变更
- 15:31 Bug #3149 (Bug-已关闭): DRL的NTC开路一侧通道不降功率
- 测试ID:Ford_SWET_3.5_0174
配置:DRL_ Failure_Report_cfg=0x01
"FAN_Activation_NTC_cfg" =3
"FAN_Activation_Te... - 15:26 功能 #3148 (已解决): TSR_004_NTC or RBIN fault:软件代码变更
- 15:26 功能 #3147 (新建): TSR_004_NTC or RBIN fault:文档及架构图变更
- 15:24 功能 #3146 (已解决): TSR_003_single or multi LED short:软件代码变更
- 15:24 功能 #3145 (新建): TSR_003_single or multi LED short:文档及架构图变更
- TSR_003 软件架构图及文档内容更新
- 15:18 Bug #3144 (Bug-不是问题): Ford_SWET_3.5_0109
- 14:46 Bug #3144 (Bug-已关闭): Ford_SWET_3.5_0109
- 条件:配置NTC功能,配置故障联动
预期结果:当NTC电阻故障时,LDM也需要按照NTC最低降功率值输出
描述:功能故障时,NTC开路时,NTC并未按照最低功率值输出,并且电流为0 - 14:22 Bug #3142 (Bug-已关闭): Buck通讯丢失反馈测试
- SPI通讯测试:
1 MOSI短路到地,理论上上电后短路应该ch1有输出,实测为全部通道都熄灭,与预期不符
2 故障信号在故障发生后的264ms就报出,不符合500ms到1s的预期结果
3 MISO短路到地,理论上上电后短路... - 13:11 Bug #3037 (Bug-问题分析): 主电源电感损坏 故障测试
- 2.0版本软件,该问题现象为:
无mainpower供电:
1 logic1(LB)和logic3(TURN)一起上电,断开mainpower后,拔掉logic1后会导致LB和TURN全部灭掉,插回logic1,LB和turn缓慢... - 12:52 Bug #3038 (Bug-已关闭): Buck短路到电源 故障测试
- 该问题在2.0版本软件上已经修复完毕,关闭问题
- 10:47 功能 #3141 (新建): Ford_SWER_0085_0004: SW FMEA
- 完成软件FMEA文档编写工作
- 10:36 功能 #3140 (新建): Ford_SSR_0085_0001_0016:TSR_019_Fault recover
- Detected no errors for 300ms, exit safe mode
SW Fault Handling time: 800ms
Safe State: NA - 10:34 功能 #3139 (新建): Ford_SSR_0085_0001_0015:TSR_017_Double invers storage
- Double invers storage of safety relevant variables shall be implemented, in case of fault, MCU shall be reset
SW F... - 10:32 功能 #3138 (已解决): Ford_SSR_0085_0001_0014:TSR_016_Internal watchdog
- Internal watchdog shall be used to monitor the incorrect operation of MCU, in case of fault, MCU shall be reset.
S... - 10:32 功能 #2519 (已关闭): Ford_SYSR: System Requirement
- 10:31 功能 #3137 (已解决): Ford_SSR_0085_0001_0013:TSR_015_Flash test
- Flash test shall be implemented during one operation cycle, in case of fault, MCU shall be reset
SW Fault Handling... - 10:30 功能 #3136 (已解决): Ford_SSR_0085_0001_0012:TSR_014_Flash ECC check
- Flash ECC shall be implemented with one bit fault correction and two bits detection, in case of two bits fault, MCU s...
- 10:29 功能 #2520 (已关闭): Ford_SYSR: FS_REQ0001_V2 LDM Input
- 10:29 功能 #2615 (已关闭): Ford_SWER_0001_0003:电源电压降功率波形
- 10:29 功能 #3135 (已解决): Ford_SSR_0085_0001_0011:TSR_013_RAM test
- RAM test shall be implemented during one operation cycle, in case of fault, MCU shall be reset
SW Fault Handling t... - 10:28 功能 #3134 (已解决): Ford_SSR_0085_0001_0010:TSR_012_ECC check
- RAM ECC shall be implemented with one bit fault correction and two bits detection, in case of two bits fault, MCU sha...
- 10:27 功能 #3133 (已解决): Ford_SSR_0085_0001_0009:TSR_011_Core test
- Cyclic core test shall be implemented, in case fault, MCU shall be reset within 1000ms
SW Fault Handling time: 800... - 10:25 功能 #3132 (新建): Ford_SSR_0085_0001_0008:TSR_010_spi communication error
- TPS92520 shall monitoring the SPI commmunication with MCU, TPS92520 shall trigger safe state to force the low beam ...
- 10:24 功能 #3131 (新建): Ford_SSR_0085_0001_0007:TSR_009_KL30 under voltage(<9V)
- MCU shall monitor Power supply of KL30,in case of under voltage(<9V), MCU shall report fault (EEL_Load0=1 and APINFO...
- 10:23 功能 #3130 (新建): Ford_SSR_0085_0001_0006:TSR_008_KL30 over voltage(>16V)
- MCU shall monitor Power supply of KL30,in case of over voltage(>16V), MCU shall report fault(EEL_Load0=1 and APINFO3...
- 10:21 功能 #3129 (新建): Ford_SSR_0085_0001_0005:TSR_007_LDM temperature fault
- MCU shall monitor the over temperature fault of the LDM
SW Fault handling time: 600ms
Safe State:
1.derate pow... - 10:19 功能 #3128 (新建): Ford_SSR_0085_0001_0004:TSR_006_Over-voltage/under-voltage fault
- MCU shall monitor the BUCK power Input provided by TPS92682, in case of abnormal voltage (out of range of paramter vo...
- 10:18 功能 #3127 (新建): Ford_SSR_0085_0001_0003:TSR_005_LED_open
- MCU shall read the output voltage of BUCK and fault status register from buck to detect open circuit , in case of ope...
- 10:16 功能 #3126 (新建): Ford_SSR_0085_0001_0002:TSR_004_NTC or RBIN fault
- MCU shall read RBIN and NTC via adc and monitor the ad value .If RBIN out of range (over range by 14300Ω or limited b...
- 10:13 功能 #3125 (新建): Ford_SSR_0085_0001_0001:TSR_003_single or multi LED short
- MCU shall read the output voltage of BUCK and detect the drop,if the drop voltage is up to the data set parameter, MC...
2024-11-27
- 15:57 Bug #3038 (Bug-问题回归验证): Buck短路到电源 故障测试
- 15:01 Bug #3124 (Bug-已关闭): Ford_SWET_3.5_582 LSSS故障联动
- 条件:配置LSSS/PWM功能,配置故障联动
预期结果:功能故障时,联动LSSS关闭?
描述:功能故障时,未联动LSSS关闭? - 14:52 Bug #3121 (Bug-问题回归验证): Ford_SWET_0025_0001_0001:转向logic信号发生器输入375ms ON/OFF,Input CH2反复断上电,outage有概率不会随点灯变化
- 14:26 Bug #3122 (Bug-问题回归验证): Ford_SWER_0029_0001:设置DRL和TL联动关系,在TL抑制DRL2/PL2正常,低边高占空比情况下恢复亮度不足,低边低占空比情况下不亮
- 11:31 Bug #3122 (Bug-问题分析): Ford_SWER_0029_0001:设置DRL和TL联动关系,在TL抑制DRL2/PL2正常,低边高占空比情况下恢复亮度不足,低边低占空比情况下不亮
- 13:15 功能 #2615: Ford_SWER_0001_0003:电源电压降功率波形
- 关联 Open issue list 161
- 11:28 Bug #3113 (Bug-新建): Ford_SWET_3.5_577 —— LSSS调光时,通道单颗/多颗短路故障是否能准确检测
- 11:25 Bug #3108 (Bug-已关闭): 电压超范围(大于16V或小于9V),不检测NTC故障,当NTC电阻超出有效范围时,LDM按正常功率输出,实测LDM按照NTC最低降功率值输出
- 11:24 Bug #3103 (Bug-挂起): LB冷启动时间超过60ms;接上CANOE,不点灯热启动37ms
- 11:18 Bug #3098 (Bug-问题回归验证): LB Failsafe模式下mian power 断开重连
- 11:09 Bug #3089: LIN通讯点灯时,IGN信号为OFF,左侧PL灯的亮灭会被右侧PL的点灯信号影响
- 复现问题
- 10:58 Bug #3067 (Bug-已关闭): 左右识别临界值3.55V略超
- 软件策略调整
- 10:54 Bug #3061 (Bug-问题回归验证): Ford_SWET_0017_0001_0003:input CH1和CH2同时从0V慢慢升至7.8V时,output CH1(近光)有几颗灯微亮,调到8V时,近光打开,但是远光会闪一下
- 回归测试
- 10:52 Bug #3042 (Bug-问题回归验证): 停发报文10s后,500ms内,发送2帧有效报文
- 10:49 Bug #3037 (Bug-问题回归验证): 主电源电感损坏 故障测试
- 回归测试
- 10:38 功能 #2914 (已关闭): Ford_SYSR: HR_REQ0087 福特测试模式V003.8 DV PV test item_Proposed
- 10:38 功能 #2960 (已关闭): Ford_SWER_0087_0041: MODE2 FAN Feedback
- #ID2923
- 10:37 错误 #2954 (已关闭): Ford_SWER_0087_0035: MODE2 FAN配置
- 无此需求
- 10:36 功能 #2951 (已关闭): Ford_SWER_0087_0034:MODE2 SBL配置
- 无此需求
- 10:30 功能 #2930 (已关闭): Ford_SWER_0087_0013:MODE1 FAN Feedback
- 硬件更改,取消AD采样端口
回归测试 - 10:19 功能 #2583 (已关闭): Ford_SYSR:FS_REQ0062_V2 LDM diagnostic with test command
- 10:19 功能 #2536 (已关闭): Ford_SYSR:FS_REQ0016_V3 PWM output configuration
- 10:17 Bug #2689 (Bug-已关闭): boost问题
- 10:14 功能 #2738: Ford_SWER_0062_0002:LDM diagnostic with test command——Read EDF2
- 5 fault logs link to #ID3123
- 10:11 功能 #2738 (已关闭): Ford_SWER_0062_0002:LDM diagnostic with test command——Read EDF2
- 回归测试,除了5次故障信息
- 10:10 功能 #2738 (已解决): Ford_SWER_0062_0002:LDM diagnostic with test command——Read EDF2
- 10:13 功能 #3123 (已解决): Ford_SWER_0062_0002:LDM diagnostic with test command——Read EDF2(5 fault logs)
- 发送诊断数据:(NAD)03 22 C0 C3
-EDF2 显示实时信息:如诊断帧信息,降功率数据,Lifetime,和- 最近5次的故障信息 -等,具体信息见附件- - 10:07 功能 #2579 (已关闭): Ford_SYSR:FS_REQ0059_V1 LIN Lost
- 回归测试
- 10:07 功能 #2711 (已关闭): Ford_SWER_0059_0011:LIN Lost- Front fog
- 回归测试
- 10:07 功能 #2710 (已关闭): Ford_SWER_0059_0010:LIN Lost- Lit star
- 回归测试
- 10:06 功能 #2709 (已关闭): Ford_SWER_0059_0009:LIN Lost- Side Marker
- 回归测试
- 10:06 功能 #2530 (已关闭): Ford_SYSR:FS_REQ0010_V1 Channel 1 Failsafe Mode
- 10:05 功能 #2530 (已解决): Ford_SYSR:FS_REQ0010_V1 Channel 1 Failsafe Mode
- 10:05 功能 #2629 (已关闭): Ford_SWER_0010_0009:Channel 1 Failsafe Mode(Channels 2-4 Assigned to LB)
- 回归测试
- 10:05 功能 #2629 (已解决): Ford_SWER_0010_0009:Channel 1 Failsafe Mode(Channels 2-4 Assigned to LB)
- 10:05 功能 #2626 (已关闭): Ford_SWER_0010_0007:Channel 1 Failsafe Mode(Static Bending)
- 回归测试
- 10:04 功能 #2626 (已解决): Ford_SWER_0010_0007:Channel 1 Failsafe Mode(Static Bending)
- 09:59 功能 #2557 (已关闭): Ford_SYSR:FS_REQ0037_V1 PWM channel Welcome/Farewell Activation
- 回归测试
- 09:59 功能 #2557 (已解决): Ford_SYSR:FS_REQ0037_V1 PWM channel Welcome/Farewell Activation
- 09:58 功能 #2548 (已关闭): Ford_SYSR:FS_REQ0028_V1 DRL Response to Low Beam outage
- 回归测试
- 09:58 功能 #2548 (已解决): Ford_SYSR:FS_REQ0028_V1 DRL Response to Low Beam outage
- 09:57 功能 #2542 (已关闭): Ford_SYSR:FS_REQ0022_V2 High Beam EEL Front Fog Activation Reaction
- 回归测试
- 09:57 功能 #2542 (已解决): Ford_SYSR:FS_REQ0022_V2 High Beam EEL Front Fog Activation Reaction
- 09:30 Bug #3082: 转向闪烁情况下,多次断上电,有概率近光灯异常打开
- 按操作步骤复现半小时,未复现故障
- 09:28 Bug #3078 (Bug-问题回归验证): 无mainpower供电
2024-11-26
- 17:13 Bug #3103: LB冷启动时间超过60ms;接上CANOE,不点灯热启动37ms
- 与主机沟通,该项是否可以让步放行
- 15:54 功能 #3019 (已关闭): Ford_SYSR:Daytime Running Lamp (DRL)/Park Lamp Drive Mode Activation
- 15:54 功能 #2605 (已关闭): Ford_SYSR:FS_REQ0084_V2 Software Flashing
- 15:53 功能 #2605 (已解决): Ford_SYSR:FS_REQ0084_V2 Software Flashing
- 15:53 功能 #2912 (已关闭): Ford_SWER_0084_0001:Software Flashing
- 15:52 功能 #2603 (已关闭): Ford_SYSR:FS_REQ0082_V1 Supplier Defined: Service Return and Development Reporting
- 15:52 功能 #2603 (已解决): Ford_SYSR:FS_REQ0082_V1 Supplier Defined: Service Return and Development Reporting
- 15:52 功能 #2876 (已关闭): Ford_SWER_0082_0003:LDM Diag service ID
- 15:51 功能 #2873 (已关闭): Ford_SWER_0082_0002:LDM Service and Diagnostics Report Frame define
- 15:50 功能 #2602 (已关闭): Ford_SYSR:FS_REQ0081_V1 Supplier Defined: Lamp Manufacturing
- 已拒绝,需求关闭
- 15:49 功能 #2870 (已关闭): Ford_SWER_0082_0001:LDM Diagnostic service requirement
- 已拒绝,关闭此需求
- 15:48 功能 #3026: Ford_SWER_ REQ26-REQ30_0006:DRL Response to Low Beam outage
- 父ID: #3019
- 15:36 Bug #3040 (Bug-已关闭): Buck通讯丢失反馈测试
- 14:36 Bug #3040 (Bug-问题回归验证): Buck通讯丢失反馈测试
- @徐永琪,回归测试
- 09:21 Bug #3040 (Bug-问题解决): Buck通讯丢失反馈测试
- 15:35 错误 #2940 (已关闭): Ford_SWER_0087_0023:Standby FAN配置
- 同ID#2923
- 15:34 功能 #2934 (已关闭): Ford_SWER_0087_0017:Standby 触发信号
- 10:09 功能 #2934 (已解决): Ford_SWER_0087_0017:Standby 触发信号
- 接上CH2即standby
- 15:34 错误 #2933 (已关闭): Ford_SWER_0087_0016:MODE1 LIN反馈信息
- !clipboard-202411261536-czdth.png!
- 15:03 Bug #3122 (Bug-已关闭): Ford_SWER_0029_0001:设置DRL和TL联动关系,在TL抑制DRL2/PL2正常,低边高占空比情况下恢复亮度不足,低边低占空比情况下不亮
- APP版本:AXY1.9
dataset见附件
问题描述:
设置DRL和TL联动关系,在TL抑制DRL2/PL2正常,低边高占空比情况下恢复亮度不足,低边低占空比情况下不亮。点PL,PL2无法恢复
操作步骤:
1、刷... - 15:02 功能 #2931 (已关闭): Ford_SWER_0087_0014:MODE1 TI Outage电压范围
- 10:40 功能 #2931 (已解决): Ford_SWER_0087_0014:MODE1 TI Outage电压范围
- 10:40 功能 #2931: Ford_SWER_0087_0014:MODE1 TI Outage电压范围
- 转向不点0V
转向点灯12.58V,电源设置13.46V
延迟27.4ms
!clipboard-202411261026-gqm8p.png!
开路可报警
!clipboard-202411261029-2wpex.png... - 15:01 功能 #2927 (已关闭): Ford_SWER_0087_0010:MODE1 FailSafe
- 08:59 功能 #2927 (已解决): Ford_SWER_0087_0010:MODE1 FailSafe
- 近光Failsafe:
低边前3颗正常点亮;低边后4颗不点亮
转向Failsafe:
15颗灯正常点亮
插上CH2随即恢复正常,灯光会闪一下 - 15:01 错误 #2923 (已关闭): Ford_SWER_0087_0007:MODE1 FAN配置
- !clipboard-202411261503-mvysi.png!
- 14:52 功能 #2957 (已关闭): Ford_SWER_0087_0038: MODE2 FailSafe
- 10:47 功能 #2957 (已解决): Ford_SWER_0087_0038: MODE2 FailSafe
- 近光Failsafe
3并9串正常点亮
转向failsafe
15串正常点亮 - 14:52 功能 #2961 (已关闭): Ford_SWER_0087_0042: MODE2 TI Outage电压范围
- 11:04 功能 #2961 (已解决): Ford_SWER_0087_0042: MODE2 TI Outage电压范围
- 转向不点0V
转向点12.7V,转向13.45V
延迟25.6ms
!clipboard-202411261059-qmuuq.png!
开路
!clipboard-202411261102-dikjn.png!
短路
... - 14:49 错误 #2918 (已关闭): Ford_SWER_0087_0002:MODE1 输出通道配置
- Ford确认,按照5%实施
- 14:47 功能 #2570 (已关闭): Ford_SYSR:FS_REQ0050_V2 LDM intermal Thermal Derating
- 14:45 功能 #2747 (已关闭): Ford_SYER_0050_0005:LDM Internal Thermal Derating for SBL
- 14:42 功能 #2535 (已关闭): Ford_SYSR:FS_REQ0015_V2 Low Side Driver 1 and 2 usage Configuration
- 14:42 功能 #2666 (已关闭): Ford_SWER_0015_0008:Low Side Driver 1 and 2 usage Configuration(SBL)
- 14:39 功能 #2555 (已关闭): Ford_SYSR:FS_REQ0035_V1 Static Bending Light Activation
- 14:38 功能 #3025 (已关闭): Ford_SWER_0035_0004:Static Bending Light Activation and Deactivation Hysteresis
- 14:31 功能 #2842 (已关闭): Ford_SWER_0035_0003:Static Bending Light Activation For App
- 14:31 功能 #2839 (已关闭): Ford_SWER_0035_0002:Static Bending Light Activation From LIN signal
- 14:30 功能 #2554 (已关闭): Ford_SYSR:FS_REQ0034_V1 Side marker Activation
- 14:29 功能 #2553 (已关闭): Ford_SYSR:FS_REQ0033_V1 Cornering Activation
- 14:29 功能 #2552 (已关闭): Ford_SYSR:FS_REQ0032_V1 Front Fog Activation
- 14:29 功能 #2551 (已关闭): Ford_SYSR:FS_REQ0031_V2_Licoln Lit Star Activation
- 14:27 功能 #3006 (已关闭): Ford_SWER_0034_0002:Right side light activation mode
- 14:27 功能 #2970 (已关闭): Ford_SWER_0031_0002:L/R Licoln Lit Star distinguish
- 14:27 功能 #2897 (已关闭): Ford_SWER_0033_0001:Cornering Activation
- 14:27 功能 #2841 (已关闭): Ford_SWER_0022_0001:High Beam EEL Front Fog Activation Reaction for App
- 14:26 功能 #2815 (已关闭): Ford_SWER_0016_0015:PWM output configuration(APP PWM Follow Static Bending light)
- 14:26 功能 #2813 (已关闭): Ford_SWER_0016_0014:PWM output configuration(APP PWM Follow Side Marker)
- 14:26 功能 #2810 (已关闭): Ford_SWER_0016_0013:PWM output configuration(APP PWM Follow Cornering light)
- 14:26 功能 #2808 (已关闭): Ford_SWER_0016_0012:PWM output configuration(APP PWM Follow Front Fog)
- 14:25 功能 #2807 (已关闭): Ford_SWER_0016_0011:PWM output configuration(APP PWM Follow Licoln Lit Star)
- 14:25 功能 #2806 (已关闭): Ford_SWER_0016_0010:PWM output configuration(APP PWM Follow DRL2)
- 14:25 功能 #2803 (已关闭): Ford_SWER_0016_0009:PWM output configuration(APP PWM Follow DRL1)
- 14:24 功能 #2895 (已关闭): Ford_SWER_0031_0001:Licoln Lit Star Activation
- 14:24 功能 #2894 (已关闭): Ford_SWER_0032_0001:Front Fog Activation
- 14:24 功能 #2890 (已关闭): Ford_SWER_0034_0001:Left side light activation mode
- 14:23 功能 #2837 (已关闭): Ford_SWER_0035_0001:Static Bending Light Activation For Dataset
- 14:22 功能 #2544 (已关闭): Ford_SYSR:FS_REQ0024_V1 Turn Indicator Delay
- 14:22 功能 #2832 (已关闭): Ford_SWER_0024_0002: Turn Indicator Delay(TI Delay Time)
- 13:16 Bug #3121 (Bug-已关闭): Ford_SWET_0025_0001_0001:转向logic信号发生器输入375ms ON/OFF,Input CH2反复断上电,outage有概率不会随点灯变化
- 软件版本:AXY1.9
dataset:默认DVX2
问题描述:
转向logic信号发生器输入375ms ON/OFF,Input CH2反复断上电,outage有概率不会随点灯变化
操作步骤:
1、Input CH... - 12:28 功能 #2928 (已关闭): Ford_SWER_0087_0011:MODE1 冷启动延时
- 10:07 功能 #2928 (已解决): Ford_SWER_0087_0011:MODE1 冷启动延时
- 近光冷启动:
正常工况冷启动48.2ms
Failsafe冷启动51.8ms
standby启动54.7ms
转向打开情况下热启动19.9ms
转向冷启动:
正常工况冷启动47.1ms
Failsafe冷启动47.1... - 09:13 功能 #2823 (已关闭): Ford_SWER_0037_0002:PWM channel Welcome/Farewell For App
- 08:42 功能 #2543 (已关闭): Ford_SYSR:FS_REQ0023_V3 Turn Indicator Activation
- 08:42 功能 #2849 (已关闭): Ford_SWER_0023_0002:Turn Indicator Activation(Turn signal working voltage judgment)
- 硬件已更改
- 08:41 功能 #2846 (已关闭): Ford_SWER_0023_0001:Turn Indicator Activation(the definition of the operational state of the Turn Indicator)
- 硬件已更改
- 08:37 Bug #2856 (Bug-已关闭): dataset问题
- 08:36 Bug #3111 (已关闭): 风扇问题
- 08:21 功能 #3105 (已关闭): Ford_SYSR: 动画逻辑
- 08:18 功能 #3001 (已关闭): Ford_SWER_0028_0002:DRL Response to Low Beam outage for App
- 08:18 功能 #2959 (已关闭): Ford_SWER_0087_0040: MODE2 电流精度
- 08:18 功能 #2932 (已关闭): Ford_SWER_0087_0015:MODE1 输出状态需求
- 08:15 功能 #3005 (已关闭): Ford_SYSR:FS_REQ003x_V1 Welcome/Frawell
- 08:14 功能 #3009 (已关闭): Ford_SWER_003x_0002:Welcome/Frawell for App
- 08:12 功能 #3017 (已关闭): Ford_SYSR:FS_REQ0029_V1 DRL Response to Turn Indicator Activation
- 08:11 错误 #2966 (已关闭): Ford_SWER_0087_0047:转向反馈信号规格
- 08:11 功能 #2962 (已关闭): Ford_SWER_0087_0043: MODE2 输出状态需求
- 08:10 功能 #2958 (已关闭): Ford_SWER_0087_0039: MODE2 冷启动延时
- 08:09 功能 #2955 (已关闭): Ford_SWER_0087_0036:MODE2 BIN配置
- 08:08 功能 #2949 (已关闭): Ford_SWER_0087_0032:MODE2 TURN功能
- 08:08 功能 #2950 (已关闭): Ford_SWER_0087_0033:MODE2 DRL/PO功能
- 08:08 功能 #2948 (已关闭): Ford_SWER_0087_0031:MODE2 HB功能
- 08:07 功能 #2947 (已关闭): Ford_SWER_0087_0030:MODE2 输出通道配置
- 08:07 功能 #2945 (已关闭): Ford_SWER_0087_0028:Standby 休眠后激活时间
- 08:06 功能 #2944 (已关闭): Ford_SWER_0087_0027:Standby 待机电流
- 08:06 功能 #2943 (已关闭): Ford_SWER_0087_0026:Standby 待机进入时间
- 08:05 功能 #2929 (已关闭): Ford_SWER_0087_0012:MODE1 电流精度
- 08:02 功能 #2965 (已关闭): Ford_SWER_0087_0046: 软启动电流控制
- 硬件需求,不影响软件控制策略
- 07:59 功能 #2537 (已关闭): Ford_SYSR:FS_REQ0017_V2 LB Activation
- 07:59 功能 #2925 (已关闭): Ford_SWER_0017_0003:LB additional channels
- 07:58 功能 #2787 (已关闭): Ford_SWER_0017_0001:LB Activation conditions
2024-11-25
- 17:46 Bug #3118 (已解决): Ford_SWET_0038_0101/102:LSD1/2配置为DRL2,发送动画信号,无动画效果
- 问题已修复,请回归验证
- 16:29 Bug #3119 (Bug-已关闭): LB Failsafe模式不满足通道开路短路故障报警
- 15:32 功能 #3006 (已解决): Ford_SWER_0034_0002:Right side light activation mode
- 15:31 功能 #2890 (已解决): Ford_SWER_0034_0001:Left side light activation mode
- 15:31 功能 #2897 (已解决): Ford_SWER_0033_0001:Cornering Activation
- 15:30 功能 #2894 (已解决): Ford_SWER_0032_0001:Front Fog Activation
- 15:30 功能 #2970 (已解决): Ford_SWER_0031_0002:L/R Licoln Lit Star distinguish
- 15:30 功能 #2895 (已解决): Ford_SWER_0031_0001:Licoln Lit Star Activation
- 15:22 功能 #2544 (已解决): Ford_SYSR:FS_REQ0024_V1 Turn Indicator Delay
- 15:21 功能 #2544 (进行中): Ford_SYSR:FS_REQ0024_V1 Turn Indicator Delay
- 15:16 支持 #3116 (已关闭): SBL 在LIN LOST时是否要进行操作,关闭LSSS或者PWM?
- 当前软件策略暂时为控制其变化
- 15:15 支持 #3109 (已关闭): NTC在低压(<9V)或者高压(>16V)情况下故障, 是否需要降功率
- 15:13 Bug #3112 (Bug-问题分析): Ford_SWET_3.5_316 TURN NTC应189万欧(-41度)开始报超范围故障并降功率,实测23万欧(-9度)开始报超范围故障并降功率
- 14:59 Bug #3111 (已解决): 风扇问题
- 已增加,风扇关闭的迟滞,请回归测试
- 14:57 功能 #2955 (已解决): Ford_SWER_0087_0036:MODE2 BIN配置
- mode2
CH1电流1449mA
CH2电流839mA
CH3电流258mA
CH4电流144mA - 14:57 功能 #3105 (已解决): Ford_SYSR: 动画逻辑
- 软件开发完毕,请更新测试用例
- 14:56 功能 #3105 (进行中): Ford_SYSR: 动画逻辑
- 14:55 功能 #2944 (已解决): Ford_SWER_0087_0027:Standby 待机电流
- 14:55 功能 #2958 (已解决): Ford_SWER_0087_0039: MODE2 冷启动延时
- 14:55 功能 #2949 (已解决): Ford_SWER_0087_0032:MODE2 TURN功能
- 14:54 功能 #2945 (已解决): Ford_SWER_0087_0028:Standby 休眠后激活时间
- 14:54 功能 #2947 (已解决): Ford_SWER_0087_0030:MODE2 输出通道配置
- 14:54 功能 #2943 (已解决): Ford_SWER_0087_0026:Standby 待机进入时间
- 14:53 功能 #2962 (已解决): Ford_SWER_0087_0043: MODE2 输出状态需求
- 14:53 功能 #2932 (已解决): Ford_SWER_0087_0015:MODE1 输出状态需求
- 低温下会触发NTC开路降功率50%
- 14:47 功能 #2950 (已解决): Ford_SWER_0087_0033:MODE2 DRL/PO功能
- 14:45 功能 #2948 (已解决): Ford_SWER_0087_0031:MODE2 HB功能
- 14:44 功能 #2959 (已解决): Ford_SWER_0087_0040: MODE2 电流精度
- Mode2实测电流精度:
Output Channel1:3.4%
Output Channel2:1.3%
Output Channel3:0.8%
Output Channel4:4% - 14:27 功能 #3027 (已关闭): Ford_SWER_ REQ26-REQ30_0007:DRL Response to Turn Indicator Activation
- 14:27 功能 #3018 (已关闭): Ford_SWER_0029_0001:DRL Response to Turn Indicator Activation
- 14:13 功能 #2929 (已解决): Ford_SWER_0087_0012:MODE1 电流精度
- Mode1实测电流精度:
Output Channel1:2.5%
Output Channel2:2.8%
Output Channel3:1.5%
Output Channel4:4.7% - 08:55 功能 #3028 (已关闭): Ford_SWER_ REQ26-REQ30_0008:DRL Response to Flash-To-Pass Activation
- 08:54 功能 #3023 (已关闭): Ford_SWER_ REQ26-REQ30_0004:DRL BCM LIN
- 08:54 功能 #3022 (已关闭): Ford_SWER_ REQ26-REQ30_0003:DRL direct wire control
- 08:49 功能 #2956 (已关闭): Ford_SWER_0087_0037: MODE2 NTC配置
- 08:48 功能 #2980 (已关闭): Ford_SYSR:FS_REQ0018&REQ0020_V1 High Beam
- 08:45 功能 #2989 (已关闭): Ford_SWER:FS_REQ0018&REQ0020_0006 High Beam LDM standard ramping for App
- 08:44 功能 #2987 (已关闭): Ford_SWER:FS_REQ0018&REQ0020_0005 High Beam BCM EEL LIN ramping for App
- 08:44 功能 #2984 (已关闭): Ford_SWER:FS_REQ0018&REQ0020_0004 High Beam channel
- 08:44 功能 #2982 (已关闭): Ford_SWER:FS_REQ0018&REQ0020_0002 High Beam ramping accuracy and frequency
- 08:43 功能 #2981 (已关闭): Ford_SWER:FS_REQ0018&REQ0020_0001 High Beam activate condition
- 08:43 功能 #2696 (已关闭): Ford_SWER_0001_0002:因CH2不可用进入Failsafe工况后,其他通道也可以作为相对应灯光的功率输入线
- 08:14 功能 #2946 (已关闭): Ford_SWER_0087_0029:MODE2 触发信号
- 08:13 功能 #2942 (已关闭): Ford_SWER_0087_0025:Standby NTC配置
- 08:13 功能 #2941 (已关闭): Ford_SWER_0087_0024:Standby BIN配置
- 08:13 功能 #2939 (已关闭): Ford_SWER_0087_0022:Standby SBL配置
- 08:12 功能 #2938 (已关闭): Ford_SWER_0087_0021:Standby DRL/PO功能
- 08:12 功能 #2937 (已关闭): Ford_SWER_0087_0020:Standby TURN功能
- 08:12 功能 #2787 (已解决): Ford_SWER_0017_0001:LB Activation conditions
- H004硬件变更,实物确认
- 08:12 功能 #2936 (已关闭): Ford_SWER_0087_0019:Standby HB功能
2024-11-22
- 19:46 功能 #2935 (已关闭): Ford_SWER_0087_0018:Standby 输出通道配置
- 19:45 功能 #2926 (已关闭): Ford_SWER_0087_0009:MODE1 NTC配置
- 19:45 功能 #2924 (已关闭): Ford_SWER_0087_0008:MODE1 BIN配置
- 19:45 功能 #2922 (已关闭): Ford_SWER_0087_0006:MODE1 SBL配置
- 19:45 功能 #2921 (已关闭): Ford_SWER_0087_0005:MODE1 DRL/PO功能
- 19:44 功能 #2920 (已关闭): Ford_SWER_0087_0004:MODE1 TURN功能
- 19:43 功能 #2919 (已关闭): Ford_SWER_0087_0003:MODE1 HB功能
- 19:40 功能 #2915 (已关闭): Ford_SWER_0087_0001:MODE1 触发信号
- 19:39 功能 #2905 (已关闭): Ford_SWER_0017_0002:LB Activation restriction
- 19:37 功能 #2896 (已关闭): Ford_SWER_0001_0006:电源电压迟滞
- 19:36 功能 #2593 (已关闭): Ford_SYSR:FS_REQ0072_V1 Node Lighting Module Configuration
- 19:36 功能 #3035 (已关闭): Ford_SWER_0072_0003:Cofig supports configuration
- 19:36 功能 #3033 (已关闭): Ford_SWER_0072_0002:Module does not support configuration
- 19:33 功能 #2838 (已关闭): Ford_SWER_0072_0001:Node Lighting Module Configuration
- 19:33 功能 #2916 (已关闭): Ford_SWER_0023_0009:Turn Indicator Activation(Turn Fault)
- 19:32 功能 #2892 (已关闭): Ford_SWER_0023_0008:Turn Indicator Activation(Two-part DRL cannot be used when DRL is combined with TI)
- 19:32 功能 #2886 (已关闭): Ford_SWER_0023_0007:Turn Indicator Activation(Copy TI behavior alternating between ‘DRL_intensity_cfg’ and ‘ParkPos_Intensity_cfg’)
- 19:32 功能 #2884 (已关闭): Ford_SWER_0023_0006:Turn Indicator Activation(Copy TI behavior alternating between DRL intensity and off)
- 19:31 功能 #2869 (已关闭): Ford_SWER_0023_0004:Turn Indicator Activation( “DRL_Combined_TI_cfg”)
- 19:31 功能 #2849: Ford_SWER_0023_0002:Turn Indicator Activation(Turn signal working voltage judgment)
- 更改硬件端口
- 19:28 功能 #2846: Ford_SWER_0023_0001:Turn Indicator Activation(the definition of the operational state of the Turn Indicator)
- 更改硬件端口(HOO4)
- 19:26 功能 #2792 (已关闭): Ford_SWER_0016_0008:PWM output configuration(APP PWM Follow TI)
- 19:25 功能 #2789 (已关闭): Ford_SWER_0016_0007:PWM output configuration(APP PWM Follow HB)
- 19:25 功能 #2788 (已关闭): Ford_SWER_0016_0006:PWM output configuration(APP PWM Follow LB)
- 19:25 功能 #2786 (已关闭): Ford_SWER_0016_0005:PWM output configuration(APP PWM unused)
- 19:25 功能 #2779 (已关闭): Ford_SWER_0016_0004:PWM output configuration(APP PWM Duty Cycle)
- 19:24 功能 #2778 (已关闭): Ford_SWER_0016_0003:PWM output configuration(APP PWM Function)
- 19:24 功能 #2570 (进行中): Ford_SYSR:FS_REQ0050_V2 LDM intermal Thermal Derating
- 16:40 功能 #2748 (已关闭): Ford_SYER_0050_0006:LDM Internal Thermal Derating Hysteresis
- 16:39 功能 #2746 (已关闭): Ford_SYER_0050_0004:LDM Internal Thermal Derating for DRL/PL
- 16:39 功能 #2744 (已关闭): Ford_SYER_0050_0003:LDM Internal Thermal Derating for Turn Indicator
- 15:37 功能 #2743 (已关闭): Ford_SYER_0050_0002:LDM Internal Thermal Derating for HB
- 15:36 功能 #2742 (已关闭): Ford_SYER_0050_0001:LDM Internal Thermal Derating for Foreground LB
- 15:34 功能 #2741 (已关闭): Ford_SWER_0062_0005:LDM diagnostic with test command——Write MEC
- 15:33 功能 #2740 (已关闭): Ford_SWER_0062_0004:LDM diagnostic with test command——Read Daataset 数据
- 15:33 功能 #2739 (已关闭): Ford_SWER_0062_0003:LDM diagnostic with test command——Read SW Version
- 15:09 功能 #2737 (已关闭): Ford_SWER_0062_0001:LDM diagnostic with test command——Read EDF1
- 15:09 功能 #2682 (已关闭): Ford_SWER_0001_0001:正常工况下,CH2通道为功率输入线,其他通道为逻辑输入线
- 15:00 功能 #2708 (已关闭): Ford_SWER_0059_0008:LIN Lost- LIN DRL
- 14:59 功能 #2707 (已关闭): Ford_SWER_0059_0007:LIN Lost- TI/LB/DRL Hardwared
- 13:27 功能 #2706 (已关闭): Ford_SWER_0059_0006:LIN Lost- HB Off
- 13:27 功能 #2702 (已关闭): Ford_SWER_0059_0004:LIN Lost- last valid frames
- 13:27 功能 #2701 (已关闭): Ford_SWER_0059_0003:LIN Lost- Recover
- 13:26 功能 #2700 (已关闭): Ford_SWER_0059_0002:LIN Lost- Above and equal Voltage
- 13:26 功能 #2699 (已关闭): Ford_SWER_0059_0001:LIN Lost-Under Voltage
- 13:25 功能 #2771 (已关闭): Ford_SWER_0015_0012:Low Side Driver 1 and 2 usage Configuration(IGN Read)
- 13:25 功能 #2670 (已关闭): Ford_SWER_0015_0011:Low Side Driver 1 and 2 usage Configuration(LSD Duty Cycle)
- 13:25 功能 #2669 (已关闭): Ford_SWER_0015_0010:Low Side Driver 1 and 2 usage Configuration(HB/FTP Base IGN)
- 13:24 功能 #2664 (已关闭): Ford_SWER_0015_0007:Low Side Driver 1 and 2 usage Configuration(DRL2)
- 13:24 功能 #2663 (已关闭): Ford_SWER_0015_0006:Low Side Driver 1 and 2 usage Configuration(HB)
- 13:23 功能 #2662 (已关闭): Ford_SWER_0015_0005:Low Side Driver 1 and 2 usage Configuration(LB)
- 13:22 功能 #2661 (已关闭): Ford_SWER_0015_0004:Low Side Driver 1 and 2 usage Configuration(Not used)
- 13:22 功能 #2977 (已关闭): Ford_SWER_0010_0011:Channel 1 Failsafe Mode
- 13:22 功能 #2695 (已关闭): Ford_SWER_0010_0010:Channel 1 Failsafe Mode(BCM failsafe mode)
- 13:21 功能 #2627 (已关闭): Ford_SWER_0010_0008:Channel 1 Failsafe Mode(Light Connected to CH1 Low Side Driver)
- 13:21 功能 #2624 (已关闭): Ford_SWER_0010_0006:Channel 1 Failsafe Mode(Active Load Fault Reporting via LIN)
- 13:21 功能 #2623 (已关闭): Ford_SWER_0010_0005:Channel 1 Failsafe Mode(N-1 Failure Detection)
- 13:03 功能 #2621 (已关闭): Ford_SWER_0010_0004:Channel 1 Failsafe Mode(Channel Open/Short Detection)
- 13:02 功能 #2620 (已关闭): Ford_SWER_0010_0003:Channel 1 Failsafe Mode(LB Bin Sense)
- 11:06 错误 #3120 (新建): LB Failsafe和正常点灯模式下配置单颗或多颗LED故障检测时,无LED故障时,LB也不能点亮
- 配置:004D7E1041028BA89EFCB228D943000000000000088C10080200000800012D2D2D2D2D2D2D008C8C8C8C8C8C8C800404040404040430005050...
- 10:51 功能 #2619 (已关闭): Ford_SWER_0010_0002:Channel 1 Failsafe Mode(LB Thermal Derating)
- 10:47 Bug #3092 (Bug-已关闭): LB Failsafe测试N-1故障无法实现
- 1.9版本有修复,但又新问题这个先关闭,重开一个详细说明
- 10:41 Bug #3119: LB Failsafe模式不满足通道开路短路故障报警
- 配置004D7E1041028BA89EFCB228D943000000000000088C10080200000800012D2D2D2D2D2D2D008C8C8C8C8C8C8C8004040404040404300050505...
- 10:38 Bug #3119 (Bug-新建): LB Failsafe模式不满足通道开路短路故障报警
- 10:37 Bug #3119 (Bug-已关闭): LB Failsafe模式不满足通道开路短路故障报警
- 步骤
1、关闭电源,上run/start档
2、input Channel1使能(L/RF_Low_Beam_Ckt置高)
3、进入Failsafe模式
4.当制造通道1开路短路故障时需要上报故障。
状况描述:进入LBFai... - 10:28 功能 #2617 (已关闭): Ford_SWER_0010_0001:Channel 1 Failsafe Mode(LB Light Output)
- 10:27 Bug #3101: LB TI Failsafe 模式下没满足N-1模式
- 那意味着TI这个问题可以关闭么,LB Failsafe N-1问题已在另外一个bug里说明
- 10:25 Bug #3093 (Bug-已关闭): LB Failsafe模式不满足LSD控制的LED不点亮
- 1.9版本已修复
- 10:24 功能 #2618 (已关闭): Ford_SWER_0001_0005:电源电压采样过滤时间
- 10:24 Bug #3099 (Bug-已关闭): Failsafe模式下LB、TI的降功率曲线不对
- 10:24 功能 #2616 (已关闭): Ford_SWER_0001_0004:电源电压降功率平滑过渡
- 10:19 功能 #2607 (已关闭): Ford_SYSR:FS_REQ0086_V1 LDM Factory Mode
- 10:16 Bug #3100 (Bug-已关闭): LB Failsafe模式下通道2、3、4配置为LB,通道2、3、4无输出
- 10:16 功能 #2605 (已关闭): Ford_SYSR:FS_REQ0084_V2 Software Flashing
- 10:16 功能 #3031 (已关闭): Ford_SWER_0084_0003: App reflash shall not erase dataset
- 09:49 功能 #3030 (已关闭): Ford_SWER_0084_0002: LDM shall be flashable via HL main connector
- 09:48 功能 #2604 (已关闭): Ford_SYSR:FS_REQ0083_V1 MSB vs. LSB
- 09:48 功能 #2911 (已关闭): Ford_SWER_0083_0001:LIN frames Data alignment
- 09:47 功能 #2599 (已关闭): Ford_SYSR:FS_REQ0078_V1 LIN Part Number Reporting
- 09:47 功能 #3011 (已关闭): Ford_SWER_0078_0003: Part Number Value
- 09:47 功能 #2889 (已关闭): Ford_SWER_0078_0001:Part Number Report
- 09:41 功能 #2885 (已关闭): Ford_SWER_0078_0002: Unused bytes handling
- 09:40 功能 #2598 (已关闭): Ford_SYSR:FS_REQ0077_V3 Run Time Configuration Validation
- 09:40 功能 #2852 (已关闭): Ford_SWER_0077_0001:Compare data of BCM broadcast frames with Cfg_match
- 09:40 功能 #2596 (已关闭): Ford_SYSR:FS_REQ0075_V1 Configuration Support
- 09:39 功能 #2893 (已关闭): Ford_SWER_0075_0003:HCM LIN node Configuration
- 09:39 功能 #2891 (已关闭): Ford_SWER_0075_0002:Left and Right LDM Node configured togther
- 09:39 功能 #2888 (已关闭): Ford_SWER_0075_0001:BCM supprot 2 different data configuration method
- 09:39 功能 #2595 (已关闭): Ford_SYSR:FS_REQ0074_V2 LIN Configuration Frame Definition
- 09:38 功能 #2877 (已关闭): Ford_SWER_0074_0002: LDM Data Configuration LIN data format
- 09:38 功能 #2871 (已关闭): Ford_SWER_0074_0001: LDM Data Configuration LIN frame format
- 09:37 功能 #2594 (已关闭): Ford_SYSR:FS_REQ0073_V1 Node Lighting Module Configuration Mechanics
- 09:37 功能 #2864 (已关闭): fORD_SWER_0073_0013: LDM Data Configuration Respond Frame Information
- 09:37 功能 #2861 (已关闭): Ford_SWER_0073_0012: LDM Data Configuration should respond “Not configured” immediately
- 09:37 功能 #2859 (已关闭): Ford_SWER_0073_0011: LDM Data Configuration Start and Over time mechanism
- 09:36 功能 #2853 (已关闭): Ford_SWER_0073_0010: LDM Data Configuration detailed information
- 09:36 功能 #2850 (已关闭): Ford_SWER_0073_0009: LDM Data Configuration LIN data frame bit map
- 09:36 功能 #2847 (已关闭): Ford_SWER_0073_0008: LDM data configuration interaction mechanism
- 09:36 功能 #2844 (已关闭): Ford_SWER_0073_0007: LDM Data Configuration LIN frame protocol
- 09:35 功能 #2843 (已关闭): Ford_SWER_0073_0006:LDM personalization configuration information
- 09:35 功能 #2840 (已关闭): Ford_SWER_0073_0005:LDM Configuration tirgger method
- 09:35 功能 #2836 (已关闭): Ford_SWER_0073_0004:LDM Configuration data transimission method
- 09:35 功能 #2833 (已关闭): Ford_SWER_0073_0004:LDM Configuration data storage mechanism
- 09:35 功能 #2831 (已关闭): Ford_SWER_0073_0002:LDM Configuration LIN message ID
- 09:34 功能 #2830 (已关闭): Ford_SWER_0073_0001:LDM Data Configuration definition
2024-11-21
- 16:32 功能 #2962: Ford_SWER_0087_0043: MODE2 输出状态需求
- CH2远光通道:
参考附件NTC阻值关系,-40℃到-14℃降功率到50%
80℃对应845mA
90℃对应745mA,约88.2%,期望降至87.5%
100℃对应637mA,约75.4%,期望降至75%
110℃对应53... - 14:38 Bug #3118 (已关闭): Ford_SWET_0038_0101/102:LSD1/2配置为DRL2,发送动画信号,无动画效果
- 配置:
LSD1_usage_cfg=0x03(DRL2)
LSD1_Duty_Cycle_cfg=20%
LSD1配置Num_LED_LSD.cgf=4
DRL_Embrace_Delay_Welcome_cfg=100... - 14:26 Bug #3094 (Bug-已关闭): 迎宾动画过程中发送宾动画信号,动画直接回退
- 实际结果:
在动画切换的时候会把亮度切换到设定亮度,开始一遍完整的动画。
A001.9验证结果通过,关闭Bug - 14:24 Bug #3095 (Bug-已关闭): 送宾动画过程中发迎宾动画信号,动画直接回退
- 实际结果:
在动画切换的时候会把亮度切换到设定亮度,开始一遍完整的动画
A001.9验证结果通过,关闭Bug - 14:22 Bug #3097 (Bug-已关闭): 送宾动画过程中点亮LB,动画没有被打断
- 预期结果:
4.动画被LB点灯信号打断,LB点亮
5.动画不会被TURN点灯信号打断,与TURN并行
实际结果:
4.动画被LB点灯信号打断,LB点亮
5.动画不会被TURN点灯信号打断,与TURN并行
A001... - 14:20 Bug #3097: 送宾动画过程中点亮LB,动画没有被打断
- 预期结果:
4.动画被LB点灯信号打断,LB点亮
5.动画不会被TURN点灯信号打断,与TURN并行
实际结果:
4.动画被LB点灯信号打断,LB点亮
5.动画不会被TURN点灯信号打断,与TURN并行
A001.... - 14:19 Bug #3096 (Bug-已关闭): 迎宾动画过程中点灯,动画没有被打断
- 13:41 功能 #2615 (反馈): Ford_SWER_0001_0003:电源电压降功率波形
- 13:01 Bug #3041: LIN 总线故障测试 -短路至GND
!clipboard-202411211301-vxr5g.png!
附件为截图- 11:36 Bug #3117 (Bug-问题分析): Ford_SWET_0048_0001_0002:mode2在NTC -40℃被判断NTC无效降功率了50%
- 10:47 Bug #3117 (Bug-已关闭): Ford_SWET_0048_0001_0002:mode2在NTC -40℃被判断NTC无效降功率了50%
- 问题描述:
mode2在NTC -40℃被判断NTC无效降功率了50%
版本信息:
AXY1.9 附件dataset
操作步骤:
1、设置NTC2电阻390KΩ
2、点灯HB
3、读取EDF1信息
结果:
... - 10:17 功能 #2592 (已关闭): Ford_SYSR:FS_REQ0071_V1 Description of Node Reporting
- 10:17 功能 #2811 (已关闭): Ford_SWER_0071_0007:APINFO0 bit map
- 10:16 功能 #2800 (已关闭): Ford_SWER_0071_0006:APINFO0 should be set to zero in all reported status
- 10:16 功能 #2798 (已关闭): Ford_SWER_0071_0005:APINFOx should follow Ford Standards
- 10:15 功能 #2797 (已关闭): Ford_SWER_0071_0004:All nodes are required to report Error Status
- 10:15 功能 #2796 (已关闭): Ford_SWER_0071_0003:Errors are reported once in LIN communicaition
- 10:15 功能 #2790 (已关闭): Ford_SWER_0071_0002:Error Status meanings in first byte for LIN communication
- 10:14 功能 #2785 (已关闭): Ford_SWER_0071_0001:Data format for first byte of LIN communication
- 10:14 功能 #2590 (已关闭): Ford_SYSR:FS_REQ0069_V1 BCM EEL LDM Node Status Report Frame
- 10:13 功能 #2882 (已关闭): Ford_SWER_0069_0004:The node that should be set to the 0x00
- 10:12 功能 #2880 (已关闭): Ford_SWER_0069_0003:LowBeam_Outage_Status feedback that the output of the LDM is faulty
- 10:11 功能 #2867 (已关闭): Ford_SWER_0069_0002:LDM_Load provide extended Load Fault Identification
- 10:11 功能 #2820 (已关闭): Ford_SWER_0069_0001:BCM EEL LDM Node Status Report Frame
- 10:11 功能 #2589 (已关闭): Ford_SYSR:FS_REQ0068_V1 Exterior Lighting Functional Support
- 10:10 功能 #2855 (已关闭): Ford_SWER_0068_0002:Exterior Lighting Functional Description
- 10:08 功能 #2854 (已关闭): Ford_SWER_0068_0001:The main lighting signal
- 10:06 功能 #2588 (已关闭): Ford_SYSR:FS_REQ0067_V1 BCM EEL Command Frame 2
- 10:06 功能 #2809 (已关闭): Ford_SWER_0067_0002:Description of the second frame of data
- 10:05 功能 #2805 (已关闭): Ford_SWER_0067_0001:the second frame from the BCM 0x01
- 10:04 功能 #2587 (已关闭): Ford_SYSR:FS_REQ0066_V1 BCM EEL Command Frame 1
- 10:03 功能 #2799 (已关闭): Ford_SWER_0066_0002:Description of the first frame of data
- 10:03 功能 #2772 (已关闭): Ford_SWER_0066_0001:the first frame from the BCM 0x00
- 10:00 功能 #2586 (已关闭): Ford_SYSR:FS_REQ0065_V1 EEL LIN Identifier Allocation
- 09:59 功能 #2860 (已关闭): Ford_SWER_0065_0001:Information
- 09:58 功能 #2585 (已关闭): Ford_SYSR:FS_REQ0064_V1 EEL LIN Message Sequencing
- 09:58 功能 #2768 (已关闭): Ford_SWER_0064_0002:After each command frame, the BCM processes the node frames
- 09:57 功能 #2765 (已关闭): Ford_SWER_0064_0001:The master node sends it in a loop
- 09:54 功能 #2584 (已关闭): Ford_SYSR:FS_REQ0063_V2 LDF
- 09:54 功能 #2729 (已关闭): Ford_SWER_0063_0001:LDF
- 09:53 功能 #2582 (已关闭): Ford_SYSR:FS_REQ0061_V3 Failure Recover strategy
- 09:53 功能 #2736 (已关闭): Ford_SWER_0061_0005:Failure Recover strategy—— Power Reset
- 09:53 功能 #2735 (已关闭): Ford_SWER_0061_0004:Failure Recover strategy—— LIN Rcv
- 09:52 功能 #2734 (已关闭): Ford_SWER_0061_0003:Failure Recover strategy——Buck Flt Rcv
- 09:52 功能 #2733 (已关闭): Ford_SWER_0061_0002:Failure Recover strategy——RBIN/NTC Rcv
- 09:52 功能 #2732 (已关闭): Ford_SWER_0061_0001:Failure Recover strategy——LED Rcv
- 09:51 功能 #2581 (已关闭): Ford_SYSR:FS_REQ006x_V2 LB Activation Redundant
- 09:51 功能 #2731 (已关闭): Ford_SWER_006x_0004:LB hardwire activate lost failure - LB Hardwire ON + Headlamp_Low_Beams_Out Off
- 09:50 功能 #2730 (已关闭): Ford_SWER_006x_0003:LB hardwire inactive and Headlamp_Low_Beams_Out ,LB shall OFF
- 09:50 功能 #2728 (已关闭): Ford_SWER_006x_0002:If either LB hardwire status and Headlamp_Low_Beams_Out ON status is ON,then LB Function shall ON
- 09:49 功能 #2727 (已关闭): Ford_SWER_006x_0001:LDM shall report the LB Outage while LB hardwire status and Headlamp_Low_Beams_Out ON status mismatch within1000ms
- 09:44 功能 #2580 (已关闭): Ford_SYSR:FS_REQ0060_V1 LIN Bus Failures
- 09:44 功能 #2724 (已关闭): Ford_SWER_0060_0008:LIN Bus Failures- report/status frame
- 09:43 功能 #2721 (已关闭): Ford_SWER_0060_0007:LIN Bus Failures- Other wires
- 09:43 功能 #2718 (已关闭): Ford_SWER_0060_0006:LIN Bus Failures- Bus Wiring Short to Battery Rcv
- 09:42 功能 #2717 (已关闭): Ford_SWER_0060_0005:LIN Bus Failures- Bus Wiring Short to Battery
- 09:41 功能 #2716 (已关闭): Ford_SWER_0060_0004:LIN Bus Failures- Bus Wiring Short to Ground Rcv
- 09:41 功能 #2715 (已关闭): Ford_SWER_0060_0003:LIN Bus Failures- Bus Wiring Short to Ground
- 09:40 功能 #2714 (已关闭): Ford_SWER_0060_0002:LIN Bus Failures-LDM Power Loss Rcv
- 09:16 功能 #2713 (已关闭): Ford_SWER_0060_0001:LIN Bus Failures-LDM Power Loss
- 09:16 功能 #2578 (已关闭): Ford_SYSR:FS_REQ0058_V1 NTC Thermistor Failure
- 09:15 功能 #2698 (已关闭): Ford_SWER_0058_0003:NTC Thermistor Failure-FAN
- 09:15 功能 #2697 (已关闭): Ford_SWER_0058_0002:NTC Thermistor Failure-out is of range
- 09:15 功能 #2694 (已关闭): Ford_SWER_0058_0001:NTC Thermistor Failure-lost
- 09:14 功能 #2577 (已关闭): Ford_SYSR:FS_REQ0057_V1 Binning Resistor Lost or Out of Range
- 09:14 功能 #2693 (已关闭): Ford_SWER_0057_0002:Binning Resistor Lost or Out of Range - Out of Range
- 09:14 功能 #2692 (已关闭): Ford_SWER_0057_0001:Binning Resistor Lost or Out of Range - Lost
- 09:13 功能 #2576 (已关闭): Ford_SYSR:FS_REQ0056_V1 Buck Failure Detection
- 09:13 功能 #2691 (已关闭): Ford_SWER_0056_0003: Buck Failure Detection - Open circuits
- 09:12 功能 #2690 (已关闭): Ford_SWER_0056_0002: Buck Failure Detection - Short to battery in HSD when it is off
- 09:12 功能 #2688 (已关闭): Ford_SWER_0056_0001: Buck Failure Detection-Short to GND
- 09:11 功能 #2575 (已关闭): Ford_SYSR:FS_REQ0055_V3 LDM Failure Response Reporting
- 09:11 功能 #3034 (已关闭): Ford_SWER_0055_0008:LDM Failure Response Reporting-Reset
- 09:11 功能 #3032 (已关闭): Ford_SWER_0055_0007:LDM Failure Response Reporting-NVM
- 09:10 功能 #2687 (已关闭): Ford_SWER_0055_0006:LDM Failure Response Reporting-TI
- 09:10 功能 #2686 (已关闭): Ford_SWER_0055_0005:LDM Failure Response Reporting-DRL Failure Report cfg
- 09:10 功能 #2685 (已关闭): Ford_SWER_0055_0004:LDM Failure Response Reporting-HB Failure Report cfg
- 09:10 功能 #2684 (已关闭): Ford_SWER_0055_0003:LDM Failure Response Reporting-LB Failure Report cfg
- 09:10 功能 #2683 (已关闭): Ford_SWER_0055_0002:LDM Failure Response Reporting-IG Status
- 09:08 功能 #2681 (已关闭): Ford_SWER_0055_0001:LDM Failure Response Reporting-Voltage range
2024-11-20
- 19:37 功能 #2943: Ford_SWER_0087_0026:Standby 待机进入时间
- 983ms
- 19:25 功能 #2945: Ford_SWER_0087_0028:Standby 休眠后激活时间
- mode2,LB/TL硬线logic点灯,PL/DRL/HB通过LIN点灯
LB:48.3ms
TL:30.5ms
DRL:53ms
PL:50ms(受限于CANoe采集精度,此数据是基于dataset设置PL占空比50%... - 18:56 功能 #2949: Ford_SWER_0087_0032:MODE2 TURN功能
- TL输入375ms ON/OFF,转向正常闪烁
- 18:52 功能 #2958: Ford_SWER_0087_0039: MODE2 冷启动延时
- mode2,硬线logic包括LB和TL:
LB:
正常工况冷启动:45.5ms
Failsafe工况冷启动:48.7ms
TL:
正常工况冷启动:49.5ms
Failsafe工况冷启动:49.5ms
- 18:23 功能 #2944: Ford_SWER_0087_0027:Standby 待机电流
- 实测仅CH2上电,连接LIN,9V时35mA;14V时36mA;16V时37mA
- 17:17 功能 #3105: Ford_SYSR: 动画逻辑
- !clipboard-202411201716-gbz3y.png!
- 17:14 Bug #3064: 近光/转向logic的高低电平判定值远低于7V
- 客户会更新电源电压曲线,按曲线进行点亮及熄灭的测试
- 15:32 Bug #3064: 近光/转向logic的高低电平判定值远低于7V
- AXY1.9复测8V开启,6V关闭。
!clipboard-202411201531-pjfbb.png!
之前是7V上下界定,有个0.5V缓冲,现在应该不需要缓冲吧? - 17:12 支持 #3116 (反馈): SBL 在LIN LOST时是否要进行操作,关闭LSSS或者PWM?
- Open issue 152条提及SBL需要在LB点亮前提下点亮;
LIN Lost时候LB不受到影响,但是SBL需要获取的车速和转弯半径丢失,这块客户没有明确,建议按丢失前维持,请评估可行性 - 17:08 支持 #3109 (反馈): NTC在低压(<9V)或者高压(>16V)情况下故障, 是否需要降功率
- 客户认可比较电源电压降功率与NTC降功率取最低功率输出的策略(Open issue 148)
- 15:47 Bug #3084: DRL不关联FTP时,先打开位置,再开启FTP,位置灯会熄灭;DRL关联FTP,先打开位置/日行,再开启FTP,均会熄灭
- AXY1.9复测,不关联,点FTP时PL会变弱且低边后面不亮;关联,点FTP时PL/DRL会变弱且低边后面不亮
- 15:37 Bug #3083: Ford_SWET_0001_0003_0007:低电压降功率截止时不自然,灯光连续闪烁后关闭
- AXY1.9复测,关断和恢复,LB低边后面的灯组均明显闪烁
- 14:47 Bug #3103: LB冷启动时间超过60ms;接上CANOE,不点灯热启动37ms
- 近光灯:
CH1+CH2上电冷启动,时间40.6ms
CH1上电冷启动,时间44.6ms
CH2有效下,CH1上电启动,时间44.6ms(多次测试取慢者)
C2有效,CH4点着DRL,CH1上电启动,时间18.3ms
转... - 12:34 Bug #3080: 所有灯低电压降功率在12V瞬间降至7V后,不会降功率,维持全额输出
- AXY1.9复测仍会出现,如上海仍然无法复现,待柯希星返回武汉后协助分析
- 12:34 Bug #3081 (Bug-已关闭): Turn配置为Invalid仍可以点亮
- 回归测试已验证OK,关闭Bug
- 10:55 Bug #3082 (Bug-问题分析): 转向闪烁情况下,多次断上电,有概率近光灯异常打开
- AXY1.9多次尝试,小概率出现近光灯闪一下
- 10:08 Bug #3102 (Bug-已关闭): 远光灯渐灭时间4000m,实际时间1s左右。渐亮比较正常
- AXY1.9复测通过,关闭
- 10:01 Bug #3061: Ford_SWET_0017_0001_0003:input CH1和CH2同时从0V慢慢升至7.8V时,output CH1(近光)有几颗灯微亮,调到8V时,近光打开,但是远光会闪一下
- AXY1.9版本复测,远光灯不会闪烁。7.8V时,近光很微亮,通道有大概3V电压
!clipboard-202411200959-xy5tn.png! - 09:44 Bug #3089: LIN通讯点灯时,IGN信号为OFF,左侧PL灯的亮灭会被右侧PL的点灯信号影响
- 尝试复现后未出现问题状况
- 09:40 Bug #3079 (Bug-已关闭): HB开启情况下,开关FTP,HB无法恢复
- AXY1.9复测通过,关闭
2024-11-19
- 15:38 支持 #3116 (已关闭): SBL 在LIN LOST时是否要进行操作,关闭LSSS或者PWM?
- SBL 在LIN LOST时是否要进行操作,关闭LSSS或者PWM?
- 15:34 Bug #3115 (Bug-已关闭): TC-LINTest-001 -LIN Status Byte 未发生变化
- 报文故障发送后,LIN Status Byte 未发生变化
- 15:33 Bug #3107 (Bug-已关闭): 电压超范围(大于16V或小于9V),不检测NTC故障,当NTC电阻超出有效范围时,LDM按正常功率输出,实测LDM按照NTC最低降功率值输出
- 13:10 Bug #3069 (Bug-已关闭): TURN RBIN故障反馈时间为0ms
- 13:08 Bug #3069 (Bug-不是问题): TURN RBIN故障反馈时间为0ms
- 13:08 Bug #3096: 迎宾动画过程中点灯,动画没有被打断
- 实际结果为:
4.动画未被点灯信号打断,LB点亮
5.动画未被点灯信号打断,TURN点亮 - 12:52 Bug #3097: 送宾动画过程中点亮LB,动画没有被打断
- LB硬线信号=OFF加入动画前置条件,动画过程中点亮LB,应退出动画,执行LB点灯
- 12:50 Bug #3108 (Bug-不是问题): 电压超范围(大于16V或小于9V),不检测NTC故障,当NTC电阻超出有效范围时,LDM按正常功率输出,实测LDM按照NTC最低降功率值输出
- 11:27 功能 #2574 (已关闭): Ford_SYSR:FS_REQ0054_V1 Load Failure Response Deactivation
- 11:27 功能 #2680 (已关闭): Ford_SWER_0054_0008:Load Failure Response Deactivation-Over Voltage range
- 11:26 功能 #2679 (已关闭): Ford_SWER_0054_0007:Load Failure Response Deactivation-N-1 Failure
- 11:23 功能 #2676 (已关闭): Ford_SWER_0054_0006:Load Failure Response Deactivation-TI Cfg
- 10:56 功能 #2673 (已关闭): Ford_SWER_0054_0005:Load Failure Response Deactivation-DRL Cfg
- 10:56 功能 #2672 (已关闭): Ford_SWER_0054_0004:Load Failure Response Deactivation-HB Cfg
- 10:55 功能 #2671 (已关闭): Ford_SWER_0054_0003:Load Failure Response Deactivation-LB Cfg
- 10:54 功能 #2667 (已关闭): Ford_SWER_0054_0002:Load Failure Response Deactivation-Temperature Range
- 10:54 功能 #2665 (已关闭): Ford_SWER_0054_0001:Load Failure Response Deactivation-Voltage range
- 10:52 功能 #2573 (已关闭): Ford_SYSR:FS_REQ0053_V2 General LED Failure Detection
- 10:51 功能 #2675 (已关闭): Ford_SWER_0053_0005:General LED Failure Detection_Power up
- 10:51 功能 #2674 (已关闭): Ford_SWER_0053_0002:General LED Failure Detection_IG status
- 10:50 功能 #2660 (已关闭): Ford_SWER_0053_0003:General LED Failure Detection_LIN feedback
- 10:50 功能 #2659 (已关闭): Ford_SWER_0053_0001:General LED Failure Detection_Voltage range
- 10:50 功能 #2657 (已关闭): Ford_SWER_0053_0004:General LED Failure Detection_All Chn
- 10:49 功能 #2578 (已解决): Ford_SYSR:FS_REQ0058_V1 NTC Thermistor Failure
- 10:48 功能 #2580 (已解决): Ford_SYSR:FS_REQ0060_V1 LIN Bus Failures
- 10:46 功能 #2572 (已关闭): Ford_SYSR:FS_REQ0052_V1_LED Thermal Derating Smooth Appearance
- 10:45 功能 #2622 (已关闭): Ford_SWER_0052_0001:LED Thermal Derating Smooth Appearance
- 10:45 功能 #2571 (已关闭): Ford_SYSR:FS_REQ0051_V1 NTC Calculation
- 10:45 功能 #2625 (已关闭): Ford_SWER_0051_0001:NTC temperature to resistance
- 10:44 功能 #2569 (已关闭): Ford_SYSR:FS_REQ0049_V2 Output Thermal Derating curve
- 10:44 功能 #2750 (已关闭): Ford_SWER_0049_0002:Output Thermal Derating Curve For App
- 10:44 功能 #2568 (已关闭): Ford_SYSR:FS_REQ0048_V1 Thermal Monitoring
- 10:44 功能 #2752 (已关闭): Ford_SWER_0048_0002:Output Channel Thermal Monitoring NTC Source Select For App
- 10:43 功能 #2567 (已关闭): Ford_SYSR:FS_REQ0047_V1 LED Thermal Derating
- 10:43 功能 #2994 (已关闭): Ford_SWER_0047_0002:LED Thermal Derating Peak Current Less Than 150mA
- 10:43 功能 #2753 (已关闭): Ford_SWER_0047_0001:LED Thermal Derating Peak Current morn than 150mA
- 10:42 功能 #2566 (已关闭): Ford_SYSR:FS_REQ0046_V1 Fan Failure Detection
- 10:42 功能 #2755 (已关闭): Ford_SWER_0046_0002:Fan Failure Detection Of App
- 10:41 功能 #2565 (已关闭): Ford_SYSR:FS_REQ0045_V2 Activation of the Fan
- 10:41 功能 #2993 (已关闭): Ford_SWER_0045_0006:NTC Temperatur Triggle Fan For App
- 10:40 功能 #2992 (已关闭): Ford_SWER_0045_0005:NTC Source Triggle Fan For App
- 10:40 功能 #2991 (已关闭): Ford_SWER_0045_0004:Activation of the Fan For App
- 10:39 功能 #2564 (已关闭): Ford_SYSR:FS_REQ0044_V1 FAN Functional self-test when power on
- 10:39 功能 #2760 (已关闭): Ford_SWER_0044_0002: FAN Functional self-test when power on for app
- 10:39 功能 #2563 (已关闭): Ford_SYSR:FS_REQ0043_V2 Bin Class Current Setting
- 10:38 功能 #2762 (已关闭): Ford_SWER_0043_0002:Bin Resistor Sample For App
- 10:38 功能 #2562 (已关闭): Ford_SYSR:FS_REQ0042_V2 Binning Resistor
- 10:37 功能 #2764 (已关闭): Ford_SWER_0042_0002:Bin Source Select For App
- 10:37 功能 #2561 (已关闭): Ford_SYSR:FS_REQ0041_V2 Channel output intensity Smooth Fading
- 10:37 功能 #2775 (已关闭): Ford_SWER_0041_0001:Channel output intensity Smooth Fading