项目

一般

简介

行为

功能 #2730

已关闭

功能 #2519: Ford_SYSR: System Requirement

功能 #2581: Ford_SYSR:FS_REQ006x_V2 LB Activation Redundant

Ford_SWER_006x_0003:LB hardwire inactive and Headlamp_Low_Beams_Out ,LB shall OFF

槐 杨8 个月 之前添加. 更新于 4 个月 之前.

状态:
已关闭
优先级:
普通
指派给:
开始日期:
2024-10-28
计划完成日期:
2024-11-07
% 完成:

100%

预期时间:

描述

目前采用LB硬线作为激活信号,当出现意外的硬线丢失时,LDM应在LB硬线激活状态与LIN信号“Headlamp_Low_Beams_Out”ON状态不匹配时报告LB硬线输入故障报告,且只有当“Headlamp_Low_Beams_Out”ON且1500ms内LB硬线无激活时才报告。
当 LB Hardwire Inactive + Headlamp_Low_Beams_Out Off时,LB 熄灭,不反馈 LB hardwire lost failure 故障。

Currently LB hardwire is used as activate signal, so in case unintended hardwire lost, LDM shall report the LB hardwire input failure report while LB hardwire active status and LIN signal "Headlamp_Low_Beams_Out" ON status mismatch, only to case that with "Headlamp_Low_Beams_Out" ON and no LB hardwire active within 1500ms。
When LB Hardwire Inactive + Headlamp_Low_Beams_Out Off, LB Off, the "LB hardwire lost failure" is not reported.

行为 #1

槐 杨 更新于 8 个月 之前

  • 描述 已更新。 (差异)
行为 #2

斌 徐 更新于 8 个月 之前

  • 计划完成日期 被设置为 2024-11-07
  • 状态新建 变更为 已解决
  • 指派给传鹏 胡 变更为 槐 杨
  • % 完成0 变更为 100

编写测试用例

行为 #3

斌 徐 更新于 7 个月 之前

  • 状态已解决 变更为 已关闭
行为 #4

希星 柯 更新于 4 个月 之前

  • 主题Ford_SWER_006x_0003:LB hardwire activate lost failure - LB Hardwire Inactive + Headlamp_Low_Beams_Out Off 变更为 Ford_SWER_006x_0003:LB hardwire inactive and Headlamp_Low_Beams_Out ,LB shall OFF

LB硬线信号和LIN信号Headlamp_Low_Beams_Out 同时为OFF,LB需熄灭

行为