已关闭

功能 #2519: Ford_SYSR: System Requirement

Ford_SYSR:FS_REQ0053_V2 General LED Failure Detection

玉洁 金8 个月 之前添加. 更新于 7 个月 之前.

状态:
已关闭
优先级:
普通
指派给:
开始日期:
2024-11-01
计划完成日期:
2024-11-07
% 完成:

100%

预期时间:
(合计: 0.00 小时)

描述

The LDM must support outage detection on all output channels. Outage detection will only occur while the channel is on, and input voltage is within the range of guaranteed performance(9-16V). Every outage needs to be communicated through LIN. The outages need to be verified at least 10 times within at least 1 second before reporting the outage. On every ‘LDM power cycle’ the outage detection is restarted.
The module must be able to detect the following defects related to LEDs:
• Single or Multiple LED Outages (per channel)
o Short anode to cathode
o Open anode to cathode
• BIN/NTC out of range

The failure shall not be reported via LIN in 500ms of LDM power up.


子任务 5 (0 打开5 已关闭)

功能 #2657: Ford_SWER_0053_0004:General LED Failure Detection_All Chn已关闭槐 杨2024-11-012024-11-07

行为
功能 #2659: Ford_SWER_0053_0001:General LED Failure Detection_Voltage range已关闭槐 杨2024-11-012024-11-07

行为
功能 #2660: Ford_SWER_0053_0003:General LED Failure Detection_LIN feedback已关闭槐 杨2024-11-012024-11-07

行为
功能 #2674: Ford_SWER_0053_0002:General LED Failure Detection_IG status已关闭槐 杨2024-11-012024-11-07

行为
功能 #2675: Ford_SWER_0053_0005:General LED Failure Detection_Power up已关闭槐 杨2024-11-012024-11-07

行为
行为 #1

涛 陆 更新于 8 个月 之前

完成

行为 #2

槐 杨 更新于 8 个月 之前

  • 状态新建 变更为 已解决
行为 #3

斌 徐 更新于 7 个月 之前

  • 状态已解决 变更为 已关闭
行为