行为
功能 #2573
已关闭功能 #2519: Ford_SYSR: System Requirement
Ford_SYSR:FS_REQ0053_V2 General LED Failure Detection
开始日期:
2024-11-01
计划完成日期:
2024-11-07
% 完成:
100%
预期时间:
(合计: 0.00 小时)
描述
The LDM must support outage detection on all output channels. Outage detection will only occur while the channel is on, and input voltage is within the range of guaranteed performance(9-16V). Every outage needs to be communicated through LIN. The outages need to be verified at least 10 times within at least 1 second before reporting the outage. On every ‘LDM power cycle’ the outage detection is restarted.
The module must be able to detect the following defects related to LEDs:
• Single or Multiple LED Outages (per channel)
o Short anode to cathode
o Open anode to cathode
• BIN/NTC out of range
The failure shall not be reported via LIN in 500ms of LDM power up.