行为
功能 #2530
已关闭功能 #2519: Ford_SYSR: System Requirement
Ford_SYSR:FS_REQ0010_V1 Channel 1 Failsafe Mode
开始日期:
2024-11-01
计划完成日期:
2024-11-14
% 完成:
100%
预期时间:
(合计: 0.00 小时)
描述
The channel1 input will be active in BCM failsafe mode, and LB and all corresponding main functions of the LB shall be operational only with “Power Supply Channel 1”( L/RF_Low_Beam_Ckt). Requirements for these specific functions will be described in following sections
Function | Failsafe Requirement |
LB Light Output | Required |
LB Thermal Derating | Required |
LB Bin Sense | Required |
Channel Open/Short Detection | Required |
N-1 Failure Detection | Required (if enabled) |
Active Load Fault Reporting via LIN | Required (if enabled) |
Static Bending | Not Required |
Light Connected to CH1 Low Side Driver | OFF |
Channels 2-4 Assigned to LB | OFF |
Table 7: Channel 1 failsafe strategy
行为