行为
功能 #2687
已关闭开始日期:
2024-11-01
计划完成日期:
2024-11-07
% 完成:
100%
预期时间:
描述
如果发生LED故障(LED串开载或短路(LED≥1个短路)),LDM应在主电源在保证性能范围内(9-18V),“Ignition_status”为“Run/Start”时,TI应始终通过硬线‘ L/RF_LED_Turn_Outage_Ckt ’反馈故障。
(In case of a LED failure (LED string open load or short circuit (LEDs ≥1 short circuit)) the LDM shall be able to report the failure via LIN bus acc. to the following parameters when main power is within the range of guaranteed performance(9-18V) and ‘Ignition_status’ is Run/Start。
TI outage shall always be reported via hard wire ’ L/RF_LED_Turn_Outage_Ckt’.