功能 #2659
已关闭
功能 #2519: Ford_SYSR: System Requirement
功能 #2573: Ford_SYSR:FS_REQ0053_V2 General LED Failure Detection
Ford_SWER_0053_0001:General LED Failure Detection_Voltage range
由 槐 杨 在 8 个月 之前添加.
更新于 7 个月 之前.
描述
故障检测仅在通道处于开启状态且输入电压(Main Power)在保证性能范围内(9-16V)时发生。
该模块必须能够检测与LED相关的以下故障:
• 单个或多个LED故障(每个通道)
• 阳极到阴极短路
• 阳极到阴极断路
• BIN/NTC超出范围
(Fault detection occurs only when the channel is on and the input voltage is within the guaranteed performance range (9-16V).
The module must be able to detect the following faults related to leds:
• Single or multiple LED failures (per channel)
• Short circuit from anode to cathode
• Anode to cathode disconnect
• BIN/NTC is out of range)
- 主题 从 Ford_SWER_0001_0001:General LED Failure Detection_Voltage range 变更为 Ford_SWER_0001_0002:General LED Failure Detection_Voltage range
- 主题 从 Ford_SWER_0001_0002:General LED Failure Detection_Voltage range 变更为 Ford_SWER_0053_0001:General LED Failure Detection_Voltage range
故障检测仅在通道处于开启状态且输入电压在保证性能范围内(9-16V)时发生。超出范围时不报故障。
该模块必须能够检测与LED相关的以下故障:
• 单个或多个LED故障(每个通道)
• 阳极到阴极短路
• 阳极到阴极断路
• BIN/NTC超出范围
(Fault detection occurs only when the channel is on and the input voltage is within the guaranteed performance range (9-16V).
The module must be able to detect the following faults related to leds:
• Single or multiple LED failures (per channel)
• Short circuit from anode to cathode
• Anode to cathode disconnect
• BIN/NTC is out of range)
- 计划完成日期 被设置为 2024-10-31
- 状态 从 新建 变更为 已解决
- 指派给 从 传鹏 胡 变更为 槐 杨
- 计划完成日期 从 2024-10-31 变更为 2024-11-07
- 开始日期 从 2024-10-28 变更为 2024-11-01
导出 Atom