槐 杨 的活动
从 2024-10-21 到 2024-10-30
2024-10-29
- 14:50 FORD LDM Localization 功能 #2890 (已关闭): Ford_SWER_0034_0001:Left side light activation mode
- 左侧sm灯的激活/停用由 BCM LIN 命令 “Position_Park_Left_Cmd”触发,该命令控制左侧节点的sm灯,其中0x00为停用sm灯,0x01为激活sm灯。
The activation/deactivatio... - 14:37 FORD LDM Localization 功能 #2882 (已关闭): Ford_SWER_0069_0004:The node that should be set to the 0x00
- 以下几个节点应被设置为0x00,包括:IntVfStat,ExtVfStat,Fade_Active,LowBeam_Outage_Status,Headlamp_Failure,LED_Temp_Not_Idle
The foll... - 14:30 FORD LDM Localization 功能 #2880 (已关闭): Ford_SWER_0069_0003:LowBeam_Outage_Status feedback that the output of the LDM is faulty
- 该信号应反馈LDM的输出故障,详情请参考
This signal shall report the LDM output fault, detail please refer to LDM failure Mode&Diagnost... - 14:01 FORD LDM Localization 功能 #2867 (已关闭): Ford_SWER_0069_0002:LDM_Load provide extended Load Fault Identification
- 节点反馈对应功能的故障,对应关系如下所示:
(xx_EEL_)Load0: Static Bending light
(xx_EEL_)Load1: LB
(xx_EEL_)Load2: HB
(xx_EEL_)Load3: ... - 13:49 FORD LDM Localization 功能 #2860 (已关闭): Ford_SWER_0065_0001:Information
- 该表格是所有LIN通讯报文的总览,具体所有ID的作用和说明,请参见上述的几张图表。
This table provides an overview of all LIN communication messages, as show... - 13:36 FORD LDM Localization 功能 #2855 (已关闭): Ford_SWER_0068_0002:Exterior Lighting Functional Description
- 外部照明功能说明的表格参考上述截图Table 30
- 13:32 FORD LDM Localization 功能 #2854 (已关闭): Ford_SWER_0068_0001:The main lighting signal
- 驱动 LDM 中 Position 和 Headlamp 逻辑的主要信号为:
Position_Park_Left_Cmd
Position_Park_Right_Cmd
Headelamps_Low_Beams_Out
He... - 13:13 FORD LDM Localization 功能 #2848 (进行中): Ford_SWER_0070_0003:How the Vehicle Operation Load Sequencing command is applied
- 车辆运行负载排序命令可以通过 BCM 的诊断命令激活单个灯负载,该消息由 5 字节的数据组成,每个 Lighting Module 1 字节。高位将启用该 Module 的负载切换。低阶 7 位将分别与软件中的单个负载相关联。当主动命...
- 13:02 FORD LDM Localization 功能 #2845 (进行中): Ford_SWER_0070_0002:The Vehicle Operation Load Sequencing command and functional correspondence
- 车辆运行负载排序命令和功能对应关系如下所示:
EX_LDM_Load_0_Rqst: Static Bending Light (All applicable light sources)
EX_LDM_Load_1_Rqst: ... - 12:34 FORD LDM Localization 功能 #2835 (反馈): Ford_SWER_0070_0001:VO_Load_Seq 0x07
- 该帧数据大小为8字节,类型为命令帧,ID为0x07,采样为80ms,该命令消息用于单独驱动每个负载,LDM需考虑左右两侧,具体需检测安装的位置。
The data size of the frame is 8 bytes, the ... - 11:30 FORD LDM Localization 功能 #2820 (已关闭): Ford_SWER_0069_0001:BCM EEL LDM Node Status Report Frame
- 节点状态报告帧,该帧大小为8字节,类型为节点状态信息,采样率小于250ms,标识符参考状态框架中的报头ID表,其中左侧ID为0x16,右侧ID为0x24
The node status report frame, the size ... - 11:10 FORD LDM Localization 功能 #2809 (已关闭): Ford_SWER_0067_0002:Description of the second frame of data
- BCM的第二帧,提供 LDM 使用的命令和状态信息。
在0x01报文中,各功能的数据组成和说明参考上述两张截图所示。
The second frame of the BCM, which provides the command ... - 11:04 FORD LDM Localization 功能 #2805 (已关闭): Ford_SWER_0067_0001:the second frame from the BCM 0x01
- BCM的第二帧,提供 LDM 使用的命令和状态信息。
该帧的数据长度为8字节,ID为0x01,类型为命令帧,采样时间为80ms
The second frame of the BCM, which provides the com... - 10:55 FORD LDM Localization 功能 #2799 (已关闭): Ford_SWER_0066_0002:Description of the first frame of data
- 在0x00报文中,各功能的数据组成和说明参考上述截图所示
WFSuperstate 在欢迎/告别过渡到 RunStart 时提供了一个小的延迟,以允许环境光 - 自动灯在位置灯中平滑地拾取功能;
Ignition_Status,F... - 09:56 FORD LDM Localization 功能 #2772 (已关闭): Ford_SWER_0066_0001:the first frame from the BCM 0x00
- BCM 中的第一帧,该帧大小为8字节,ID为0x00,类型为命令帧,采样时间为80ms。
The first frame in the BCM, the frame size is 8 bytes, the ID is 0x00, ... - 09:30 FORD LDM Localization 功能 #2768 (已关闭): Ford_SWER_0064_0002:After each command frame, the BCM processes the node frames
- 在每个命令帧之后,BCM 将处理一个节点帧,循环遍历 LIN 节点,包含以下三个响应节点:左节点,右节点和尾灯节点以及无响应周期。
After each command frame, the BCM will process a n... - 09:26 FORD LDM Localization 功能 #2765 (已关闭): Ford_SWER_0064_0001:The master node sends it in a loop
- BCM 在两个功能命令帧之间交替,命令帧分为Master Functional 1和Master Functional 2两个主节点。
The BCM alternates between two function command ...
2024-10-28
- 18:25 FORD LDM Localization 功能 #2573 (已解决): Ford_SYSR:FS_REQ0053_V2 General LED Failure Detection
- 18:22 FORD LDM Localization 功能 #2741 (已关闭): Ford_SWER_0062_0005:LDM diagnostic with test command——Write MEC
- 发送诊断写数据:(NAD)04 2E F1 A0 MEC
反馈显示写入成功或失败 - 18:19 FORD LDM Localization 功能 #2740 (已关闭): Ford_SWER_0062_0004:LDM diagnostic with test command——Read Daataset 数据
- 发送诊断数据:(NAD)03 22 C0 C1
反馈显示Dataset数据信息:如通道配置,LSD配置,FAN配置,NTC配置等,具体信息见附件 - 18:16 FORD LDM Localization 功能 #2739 (已关闭): Ford_SWER_0062_0003:LDM diagnostic with test command——Read SW Version
- 发送诊断数据:(NAD)03 22 C0 C0
SW Version 显示软件版本信息:如程序版本,Dataset版本,项目版本等,具体信息见附件 - 18:13 FORD LDM Localization 功能 #2738 (已关闭): Ford_SWER_0062_0002:LDM diagnostic with test command——Read EDF2
- 发送诊断数据:(NAD)03 22 C0 C3
EDF2 显示实时信息:如诊断帧信息,降功率数据,Lifetime,和最近5次的故障信息等,具体信息见附件 - 18:09 FORD LDM Localization 功能 #2737 (已关闭): Ford_SWER_0062_0001:LDM diagnostic with test command——Read EDF1
- 发送诊断数据:(NAD)03 22 C0 C2
EDF1 显示实时信息:如通道电流,电源电压,升压电压,通道Vf, Rbin电阻范围,内部和外部温度等,具体信息见附件 - 17:46 FORD LDM Localization 功能 #2736 (已关闭): Ford_SWER_0061_0005:Failure Recover strategy—— Power Reset
- 本章所述的所有LDM故障应在以下情况下恢复:
ldm上电复位
All the LDM failure above in this chapter shall recovery when:
LDM power on re... - 17:45 FORD LDM Localization 功能 #2735 (已关闭): Ford_SWER_0061_0004:Failure Recover strategy—— LIN Rcv
- 本章所述的所有LDM故障应在以下情况下恢复:
ldm在500毫秒内接收3个有效的LIN信号
All the LDM failure above in this chapter shall recovery when:
... - 17:44 FORD LDM Localization 功能 #2734 (已关闭): Ford_SWER_0061_0003:Failure Recover strategy——Buck Flt Rcv
- 本章所述的所有LDM故障应在以下情况下恢复:
buck通道短/开路故障恢复, 自恢复
All the LDM failure above in this chapter shall recovery when:
Bu... - 17:42 FORD LDM Localization 功能 #2733 (已关闭): Ford_SWER_0061_0002:Failure Recover strategy——RBIN/NTC Rcv
- RBIN不可自恢复,需要重新上电;
NTC可以自恢复。 - 17:41 FORD LDM Localization 功能 #2732 (已关闭): Ford_SWER_0061_0001:Failure Recover strategy——LED Rcv
- 本章所述的所有LDM故障应在以下情况下恢复:
•led负载恢复正常工作
All the LDM failure above in this chapter shall recovery when:
LED load re... - 17:35 FORD LDM Localization 功能 #2731 (已关闭): Ford_SWER_006x_0004:LB hardwire activate lost failure - LB Hardwire ON + Headlamp_Low_Beams_Out Off
- 目前采用LB硬线作为激活信号,当出现意外的硬线丢失时,LDM应在LB硬线激活状态与LIN信号“Headlamp_Low_Beams_Out”ON状态不匹配时报告LB硬线输入故障报告,且只有当“Headlamp_Low_Beams_...
- 17:33 FORD LDM Localization 功能 #2730 (已关闭): Ford_SWER_006x_0003:LB hardwire inactive and Headlamp_Low_Beams_Out ,LB shall OFF
- 目前采用LB硬线作为激活信号,当出现意外的硬线丢失时,LDM应在LB硬线激活状态与LIN信号“Headlamp_Low_Beams_Out”ON状态不匹配时报告LB硬线输入故障报告,且只有当“Headlamp_Low_Beams_...
- 17:27 FORD LDM Localization 功能 #2729 (已关闭): Ford_SWER_0063_0001:LDF
- 在BCM LIN(10417波特率)上,LDM应使用“LDF BCM_G2_LIN_05_Ckt_v17_2016Dec01.LDF”
The LDM shall consider LDF BCM_G2_LIN_05_Ckt_v... - 17:07 FORD LDM Localization 功能 #2728 (已关闭): Ford_SWER_006x_0002:If either LB hardwire status and Headlamp_Low_Beams_Out ON status is ON,then LB Function shall ON
- 17:01 FORD LDM Localization 功能 #2727 (已关闭): Ford_SWER_006x_0001:LDM shall report the LB Outage while LB hardwire status and Headlamp_Low_Beams_Out ON status mismatch within1000ms
- 目前采用LB硬线作为激活信号,当出现意外的硬线丢失时,LDM应在LB硬线激活状态与LIN信号“Headlamp_Low_Beams_Out”ON状态不匹配时报告LB硬线输入故障报告,且需1000ms报告。
关联Open is... - 16:48 FORD LDM Localization 功能 #2724 (已关闭): Ford_SWER_0060_0008:LIN Bus Failures- report/status frame
- 诊断反馈仅对报告/状态帧有效。其余帧不反馈诊断信息。
Diagnostic purposes is only valid for report/status frame. - 16:40 FORD LDM Localization 功能 #2721 (已关闭): Ford_SWER_0060_0007:LIN Bus Failures- Other wires
- 除电源、接地或串行数据外,ECU的任何单线电路短路或断路不应妨碍与该ECU进行诊断通信的能力。
A short or open in any single wiring circuit of an ECU, except for... - 16:37 FORD LDM Localization 功能 #2718 (已关闭): Ford_SWER_0060_0006:LIN Bus Failures- Bus Wiring Short to Battery Rcv
- 当总线短接电源 故障排除后,在功能延迟章节确定的时间内,无需操作员干预即可恢复正常操作。
Upon removal of the fault, normal operation shall resume without any ... - 16:35 FORD LDM Localization 功能 #2717 (已关闭): Ford_SWER_0060_0005:LIN Bus Failures- Bus Wiring Short to Battery
- 当母线短接正极电池小于26.5 V (Vbatt < 26.5 V)时,网络数据通信可能中断,但不会损坏任何设备。母线与电池之间的网络阻抗小于50 Ω应视为短接,不保证或不要求继续通信。
Network data communi... - 16:31 FORD LDM Localization 功能 #2716 (已关闭): Ford_SWER_0060_0004:LIN Bus Failures- Bus Wiring Short to Ground Rcv
- LIN短路至地故障排除后,在功能延迟章节REQ0040(#2560), 确定的时间内,无需操作员干预即可恢复正常操作。
Upon removal of the fault, normal operation shall resu... - 16:30 FORD LDM Localization 功能 #2715 (已关闭): Ford_SWER_0060_0003:LIN Bus Failures- Bus Wiring Short to Ground
- 母线和地之间的网络阻抗小于50 Ω应被认为是短地,不保证或不需要继续通信。网络数据通信可能中断,但当总线接地短路时,不会损坏任何ECU。
Network data communications may be interrupte... - 16:28 FORD LDM Localization 功能 #2714 (已关闭): Ford_SWER_0060_0002:LIN Bus Failures-LDM Power Loss Rcv
- 恢复正常电源后,在功能延迟章节REQ0040(#ID2560),规定的时间内,无需操作人员干预即可恢复正常操作。
Upon return to normal power, normal operation shall resum... - 16:25 FORD LDM Localization 功能 #2713 (已关闭): Ford_SWER_0060_0001:LIN Bus Failures-LDM Power Loss
- LDM功率损耗- LDM在功率损耗(或低电压)情况下不会干扰其余总线ecu (LDM, HCM)之间的正常通信。
LDM Power Loss – LDM shall not interfere with normal comm... - 16:12 FORD LDM Localization 功能 #2711 (已关闭): Ford_SWER_0059_0011:LIN Lost- Front fog
- 如果LIN丢失,前雾将被取消。
Front fog is to be deactivated in case of LIN lost. - 16:10 FORD LDM Localization 功能 #2710 (已关闭): Ford_SWER_0059_0010:LIN Lost- Lit star
- 如果LIN丢失,Lit star灯将被停用。
Lit star is to be deactivated in case of LIN lost. - 16:08 FORD LDM Localization 功能 #2709 (已关闭): Ford_SWER_0059_0009:LIN Lost- Side Marker
- 如果LIN丢失,SM灯将被激活。
Side Marker is to be activated in case of LIN lost. - 16:05 FORD LDM Localization 功能 #2708 (已关闭): Ford_SWER_0059_0008:LIN Lost- LIN DRL
- If DRL/PL configured with LIN triggle,software should control DRL is to be activated with ‘ParkPos_Intensity_cfg’ in ...
- 16:04 FORD LDM Localization 功能 #2707 (已关闭): Ford_SWER_0059_0007:LIN Lost- TI/LB/DRL Hardwared
- TI/LB/DRL Hardwared 激活不依赖于LIN信号,也没有任何LIN丢失的故障模式
TI/LB/Hardwired DRL activation are not dependent on LIN signals an... - 16:01 FORD LDM Localization 功能 #2706 (已关闭): Ford_SWER_0059_0006:LIN Lost- HB Off
- Software should turn off HB,when LIN lost occured.
- 15:53 FORD LDM Localization 功能 #2702 (已关闭): Ford_SWER_0059_0004:LIN Lost- last valid frames
如果收到损坏的帧,软件将按最后接收到的有效帧执行,维持最后一帧状态输出.
If corrupt frames are received, the last valid frames shall be used in the ...- 15:47 FORD LDM Localization 功能 #2701 (已关闭): Ford_SWER_0059_0003:LIN Lost- Recover
如果LDM在500ms内接收到3个有效的LIN信号,LDM将恢复正常工作。
The LDM shall go back to normal function if the LDM receives 3 valid LIN s...- 15:45 FORD LDM Localization 功能 #2700 (已关闭): Ford_SWER_0059_0002:LIN Lost- Above and equal Voltage
模块main power电压大于等于7V时,2000ms (+/- 50mS)无LIN消息或损坏LIN消息,会出现“LIN丢失”的情况:
A “LIN lost” situation occurs if:
2000...- 15:44 FORD LDM Localization 功能 #2699 (已关闭): Ford_SWER_0059_0001:LIN Lost-Under Voltage
当模块main power电压低于7V时,5000ms (+/- 50mS)没有收到LIN消息或损坏的LIN消息,会出现“LIN丢失”的情况:
A “LIN lost” situation occurs if:
5...- 15:38 FORD LDM Localization 功能 #2698 (已关闭): Ford_SWER_0058_0003:NTC Thermistor Failure-FAN
- 如果NTC电阻丢失或者超出范围,且功能/FAN绑定该NTC的时候,分配的FAN需运行
(Even if there is a Fan attached, the LDM shall run the Fan.) - 15:35 FORD LDM Localization 功能 #2697 (已关闭): Ford_SWER_0058_0002:NTC Thermistor Failure-out is of range
- 如果NTC电阻超出范围:
1. 如果配置了NTC降额,LED按照最低降额点输出;
2. 如果没有配置NTC降额,led 应由RBIN电阻定义的电流驱动
(If the NTC resistor is lost or its va... - 15:31 FORD LDM Localization 功能 #2694 (已关闭): Ford_SWER_0058_0001:NTC Thermistor Failure-lost
- 如果NTC电阻丢失:
1. 如果配置了NTC降额,LED按照最低降额点输出;
2. 如果没有配置NTC降额,led 应由RBIN电阻定义的电流驱动
(If the NTC resistor is lost or its valu... - 15:25 FORD LDM Localization 功能 #2693 (已关闭): Ford_SWER_0057_0002:Binning Resistor Lost or Out of Range - Out of Range
- 如果RBIN电阻超出范围,不应导致通道过流超过BCM电流限制,LDM使用模块存储的历史档位,实现电流输出
(If the binning resistor is lost (short circuit or open circu... - 15:24 FORD LDM Localization 功能 #2692 (已关闭): Ford_SWER_0057_0001:Binning Resistor Lost or Out of Range - Lost
- 如果RBIN电阻丢失(未识别到有效档位),不应导致通道过流超过BCM电流限制,LDM使用模块存储的历史档位,实现电流输出
(If the binning resistor is lost (short circuit or op... - 15:19 FORD LDM Localization 功能 #2691 (已关闭): Ford_SWER_0056_0003: Buck Failure Detection - Open circuits
- buck自身检测到的失败如下:
开路
(The failures that the buck itself detects are the followings:
Open circuits
)
!c... - 15:19 FORD LDM Localization 功能 #2690 (已关闭): Ford_SWER_0056_0002: Buck Failure Detection - Short to battery in HSD when it is off
- buck自身检测到的失败如下:
HSD关闭时,HSD短路到电源
(The failures that the buck itself detects are the followings:
o Short... - 15:14 FORD LDM Localization 功能 #2688 (已关闭): Ford_SWER_0056_0001: Buck Failure Detection-Short to GND
- buck自身检测到的失败如下:
短接GND
(The failures that the buck itself detects are the followings:
Short to GND
)
!... - 15:10 FORD LDM Localization 功能 #2687 (已关闭): Ford_SWER_0055_0006:LDM Failure Response Reporting-TI
- 如果发生LED故障(LED串开载或短路(LED≥1个短路)),LDM应在主电源在保证性能范围内(9-18V),“Ignition_status”为“Run/Start”时,TI应始终通过硬线‘ L/RF_LED_Turn_Outage...
- 15:08 FORD LDM Localization 功能 #2686 (已关闭): Ford_SWER_0055_0005:LDM Failure Response Reporting-DRL Failure Report cfg
- 如果发生LED故障(LED串开载或短路(LED≥1个短路)),LDM应在主电源在保证性能范围内(9-18V),“Ignition_status”为“Run/Start”时,通过配置实现是否通过LIN总线报告故障。
(In cas... - 15:06 FORD LDM Localization 功能 #2685 (已关闭): Ford_SWER_0055_0004:LDM Failure Response Reporting-HB Failure Report cfg
- 如果发生LED故障(LED串开载或短路(LED≥1个短路)),LDM应在主电源在保证性能范围内(9-18V),“Ignition_status”为“Run/Start”时,通过配置实现是否通过LIN总线报告故障。
(In cas... - 15:05 FORD LDM Localization 功能 #2684 (已关闭): Ford_SWER_0055_0003:LDM Failure Response Reporting-LB Failure Report cfg
- 如果发生LED故障(LED串开载或短路(LED≥1个短路)),LDM应在主电源在保证性能范围内(9-18V),“Ignition_status”为“Run/Start”时,通过配置实现是否通过LIN总线报告故障。
(In cas... - 15:02 FORD LDM Localization 功能 #2683 (已关闭): Ford_SWER_0055_0002:LDM Failure Response Reporting-IG Status
- 如果发生LED故障(LED串开载或短路(LED≥1个短路)),LDM应在主电源在保证性能范围内(9-18V),“Ignition_status”为“Run/Start”时,能够通过LIN总线报告故障。
(In case of a... - 15:02 FORD LDM Localization 功能 #2681 (已关闭): Ford_SWER_0055_0001:LDM Failure Response Reporting-Voltage range
- (In case of a LED failure (LED string open load or short circuit (LEDs ≥1 short circuit(parameter xx_Failure_Deact_cf...
- 14:50 FORD LDM Localization 功能 #2680 (已关闭): Ford_SWER_0054_0008:Load Failure Response Deactivation-Over Voltage range
- 输入电压超出9-16V范围后,不反馈其余故障,仅反馈输入故障
(When the input voltage exceeds the range of 9-16V, no fault is reported, only unde... - 14:46 FORD LDM Localization 功能 #2679 (已关闭): Ford_SWER_0054_0007:Load Failure Response Deactivation-N-1 Failure
- 注:当N-1 LED单光功能失效时,其他功能继续工作。
示例:当LSD的led失效时,下一个更高的子系统(例如,High Side Driver)仍将根据上述参数工作。
NOTE: In case of N-1 LED fai... - 14:37 FORD LDM Localization 功能 #2676 (已关闭): Ford_SWER_0054_0006:Load Failure Response Deactivation-TI Cfg
- 如果发生故障(1个或多个LED开载或短路),受影响组件的下一个更高的子系统(整个LED串)是否停用,可以通过参数进行配置。
‘ TI_ Failure_Deact_cfg ’参数定义:
•0x00:不需要去激活
•0x01:在检... - 14:32 FORD LDM Localization 功能 #2675 (已关闭): Ford_SWER_0053_0005:General LED Failure Detection_Power up
- 在LDM通电500毫秒内,不能通过LIN报告故障。在每次“LDM电源循环”期间,故障检测将重新开始。
该模块必须能够检测与LED相关的以下故障:
• 单个或多个LED故障(每个通道)
• 阳极到阴极短路
• 阳极到阴极... - 14:29 FORD LDM Localization 功能 #2660: Ford_SWER_0053_0003:General LED Failure Detection_LIN feedback
- 在1s内反馈故障
- 11:11 FORD LDM Localization 功能 #2660 (已关闭): Ford_SWER_0053_0003:General LED Failure Detection_LIN feedback
- 每次故障都需要通过LIN进行通信。在报告故障之前,需要至少在1秒内对故障进行10次验证。
该模块必须能够检测与LED相关的以下故障:
• 单个或多个LED故障(每个通道)
• 阳极到阴极短路
• 阳极到阴极断路
• BIN/... - 14:29 FORD LDM Localization 功能 #2674 (已关闭): Ford_SWER_0053_0002:General LED Failure Detection_IG status
- 在每个“LDM电源周期”中(模块重新上电),重新启动停机检测。
(On every ‘LDM power cycle’ the outage detection is restarted.) - 14:21 FORD LDM Localization 功能 #2659: Ford_SWER_0053_0001:General LED Failure Detection_Voltage range
故障检测仅在通道处于开启状态且输入电压在保证性能范围内(9-16V)时发生。超出范围时不报故障。
该模块必须能够检测与LED相关的以下故障:
• 单个或多个LED故障(每个通道)
• 阳极到阴极短路
• 阳极到...- 11:09 FORD LDM Localization 功能 #2659 (已关闭): Ford_SWER_0053_0001:General LED Failure Detection_Voltage range
- 故障检测仅在通道处于开启状态且输入电压(Main Power)在保证性能范围内(9-16V)时发生。
该模块必须能够检测与LED相关的以下故障:
• 单个或多个LED故障(每个通道)
• 阳极到阴极短路
• 阳极到阴极断路
... - 14:10 FORD LDM Localization 功能 #2673 (已关闭): Ford_SWER_0054_0005:Load Failure Response Deactivation-DRL Cfg
- 如果发生故障(1个或多个LED开载或短路),受影响组件的下一个更高的子系统(整个LED串)是否停用,可以通过参数进行配置。
‘ DRL_ Failure_Deact_cfg ’参数定义:
•0x00:不需要去激活
•0x01:在... - 13:52 FORD LDM Localization 功能 #2672 (已关闭): Ford_SWER_0054_0004:Load Failure Response Deactivation-HB Cfg
- 如果发生故障(1个或多个LED开载或短路),受影响组件的下一个更高的子系统(整个LED串)是否停用,可以通过参数进行配置。
‘ HB_ Failure_Deact_cfg ’参数定义:
•0x00:不需要去激活
•0x01:在检... - 13:49 FORD LDM Localization 功能 #2671 (已关闭): Ford_SWER_0054_0003:Load Failure Response Deactivation-LB Cfg
- 如果发生故障(1个或多个LED开载或短路),受影响组件的下一个更高的子系统(整个LED串)是否停用,可以通过参数进行配置。
‘ LB_Failure_Deact_cfg ’参数定义:
•0x00:不需要去激活
•0x01:在... - 12:51 FORD LDM Localization 功能 #2667 (已关闭): Ford_SWER_0054_0002:Load Failure Response Deactivation-Temperature Range
- LED断电检测应在-40℃至110℃环境温度范围内工作。
(LED outage detection shall work within -40 to 110°C ambient temperature range) - 12:50 FORD LDM Localization 功能 #2665 (已关闭): Ford_SWER_0054_0001:Load Failure Response Deactivation-Voltage range
- LED断电检测输入电压范围为9-16V。如果输入电压超出范围,则不报告LED断电。
( Input voltage range for LED outage detection is 9-16V. No LED outages... - 11:03 FORD LDM Localization 功能 #2657 (已关闭): Ford_SWER_0053_0004:General LED Failure Detection_All Chn
- 该LDM必须支持对所有输出通道的故障检测,该模块必须能够检测与LED相关的以下故障:
• 单个或多个LED故障(每个通道)
• 阳极到阴极短路
• 阳极到阴极断路
• BIN/NTC超出范围
(The LDM must ...
2024-10-23
- 16:11 FORD LDM Localization Bug #2513 (Bug-问题回归验证): 单元测试测试问题反馈
- 1.app_dpl 代码最后存在PWM重复赋值计算,需删除
2.app_fan fan状态为error时,fan赋值错误,未停止fan,需分析修改 - 16:04 FORD LDM Localization Task #2509: Ford_SWET: DV&PV Software Test
- 完成A001.6版本单元测试,静态测试,LIN一致性测试及报告更新
等待A001.8版本发布
导出 Atom