斌 徐 的活动
从 2024-10-20 到 2024-10-29
2024-10-29
- 17:21 FORD LDM Localization 功能 #2803 (进行中): Ford_SWER_0016_0009:PWM output configuration(APP PWM Follow DRL1)
- 16:16 FORD LDM Localization 功能 #2527: Ford_SYSR:FS_REQ0007_V1 TI Power Mode
- tolerance should be double confirmed next meeting
- 15:20 FORD LDM Localization 功能 #2615: Ford_SWER_0001_0003:电源电压降功率波形
- 2024/10/29 与福特点检会议,硬件工程师(贾日晶)核实,待硬件确认,明天给出反馈
- 15:17 FORD LDM Localization 功能 #2615: Ford_SWER_0001_0003:电源电压降功率波形
- 2024/10/29 与福特点检会议,硬件工程师(贾日晶)核实: 6V降功率到30%,硬件可以实现
- 15:02 FORD LDM Localization 功能 #2893 (已解决): Ford_SWER_0075_0003:HCM LIN node Configuration
- HCM requirements
- 15:00 FORD LDM Localization 功能 #2893 (已关闭): Ford_SWER_0075_0003:HCM LIN node Configuration
- The HCM will also support LIN node configuration on each of its private LIN0 and LIN1 connections to the LDM.
- 15:01 FORD LDM Localization 功能 #2891 (已解决): Ford_SWER_0075_0002:Left and Right LDM Node configured togther
- 14:50 FORD LDM Localization 功能 #2891 (已关闭): Ford_SWER_0075_0002:Left and Right LDM Node configured togther
- The LF_EEL and RF_EEL will be configured together (Both get the same data) and the EX_EEL (FCM) is configured indepen...
- 15:00 FORD LDM Localization 功能 #2888 (已解决): Ford_SWER_0075_0001:BCM supprot 2 different data configuration method
- BCM requirements
- 14:48 FORD LDM Localization 功能 #2888 (已关闭): Ford_SWER_0075_0001:BCM supprot 2 different data configuration method
- BCM will support configuration of the LIN nodes using the established methods for configuration that are already in p...
- 14:36 FORD LDM Localization 功能 #2881 (已解决): Ford_SWER_0074_0003: LDM Data Configuration Requirement For BCM
- BCM requirements, close directly
- 14:35 FORD LDM Localization 功能 #2881 (已关闭): Ford_SWER_0074_0003: LDM Data Configuration Requirement For BCM
- The BCM methodology utilizes a data space which contains the multiple variant configurations for LIN Nodes.
If the... - 14:29 FORD LDM Localization 功能 #2879 (已关闭): Ford_SWER_0074_0003: LDM Configuration Matching test
- -The first 2 Bytes (Data0 and Data1) of ConfigIndex = 0 are reserved for BCM to LDM Configuration Matching test.-
... - 14:26 FORD LDM Localization 功能 #2877 (已关闭): Ford_SWER_0074_0002: LDM Data Configuration LIN data format
- !clipboard-202410291428-lorlm.png!
Table 41: BCM Front EEL Configuration Frame Definition - 14:19 FORD LDM Localization 功能 #2871 (已关闭): Ford_SWER_0074_0001: LDM Data Configuration LIN frame format
- !clipboard-202410291426-qokys.png!
Table 40: BCM Front EEL Configuration Frame
- 13:58 FORD LDM Localization 功能 #2864 (已关闭): fORD_SWER_0073_0013: LDM Data Configuration Respond Frame Information
- |DLPL_LIN_19_007 |Note 1: The node can detect that it has received all ConfigData when the ConfigIndex is zero the s...
- 13:53 FORD LDM Localization 功能 #2861 (已关闭): Ford_SWER_0073_0012: LDM Data Configuration should respond “Not configured” immediately
- |DLPL_LIN_19_005 |Once a node detects that the subnet as switched to Configuration Mode then it shall immediately st...
- 13:49 FORD LDM Localization 功能 #2859 (已关闭): Ford_SWER_0073_0011: LDM Data Configuration Start and Over time mechanism
- |DLPL_LIN_19_004 |A node shall infer that Configuration Mode has started when it first receives any of these signals...
- 13:38 FORD LDM Localization 功能 #2638 (已解决): Ford_SWER_0011_0006:Turn Indicator Failsafe Mode(Active Load Fault Reporting via LIN)
- 13:37 FORD LDM Localization 功能 #2843 (已解决): Ford_SWER_0073_0006:LDM personalization configuration information
- 12:50 FORD LDM Localization 功能 #2843 (已关闭): Ford_SWER_0073_0006:LDM personalization configuration information
- Reserved, no Software requirements
- 12:49 FORD LDM Localization 功能 #2843 (已关闭): Ford_SWER_0073_0006:LDM personalization configuration information
- If the information can change, it is deemed to be personalization information and must be transmitted to the node us...
- 13:31 FORD LDM Localization 功能 #2853 (已关闭): Ford_SWER_0073_0010: LDM Data Configuration detailed information
- The LDM supplier is responsible for providing full multiplexing information showing the location of each parameter wi...
- 13:23 FORD LDM Localization 功能 #2850 (已关闭): Ford_SWER_0073_0009: LDM Data Configuration LIN data frame bit map
- DLPL_LIN_19_002 – Configuration Data Mapping
The table below explicitly lists how the multiplexed Config informati... - 13:08 FORD LDM Localization 功能 #2847 (已关闭): Ford_SWER_0073_0008: LDM data configuration interaction mechanism
- A LIN Node will "know" that it has completely received all the ConfigData when it sees ConfigIndex = 0 a second time....
- 12:53 FORD LDM Localization 功能 #2844 (已关闭): Ford_SWER_0073_0007: LDM Data Configuration LIN frame protocol
- To avoid limiting the amount of configuration information to what can fit into one LIN frame, we have chosen to use a...
- 12:46 FORD LDM Localization 功能 #2840 (已关闭): Ford_SWER_0073_0005:LDM Configuration tirgger method
- Configuration information is limited to data that is downloaded when the LIN node is first installed and never changes.
- 12:37 FORD LDM Localization 功能 #2836 (已关闭): Ford_SWER_0073_0004:LDM Configuration data transimission method
- To support a relatively large amount of configuration info (inclination/intrusion sensor) a multiplex message is used...
- 12:30 FORD LDM Localization 功能 #2833 (已关闭): Ford_SWER_0073_0004:LDM Configuration data storage mechanism
- The LIN node must retain this configuration information in EEPROM (or equivalent)
- 12:26 FORD LDM Localization 功能 #2831 (已关闭): Ford_SWER_0073_0002:LDM Configuration LIN message ID
- Lin controller message ID (0x05) is used to LDM Data configuration
The nodes respond IDs are listed as below:
0x1... - 12:24 FORD LDM Localization 功能 #2830 (已关闭): Ford_SWER_0073_0001:LDM Data Configuration definition
- The function message (Message ID refer to: Ford_SWER_0073_0002) used to LDM configuration can not used to download ap...
- 11:13 FORD LDM Localization 功能 #2811 (已关闭): Ford_SWER_0071_0007:APINFO0 bit map
|APINFO4 |APINFO3 |APINFO2 |APINFO1 |APINFO0 |Meaning|
|0 |0 |0 |0 |unused ...- 10:57 FORD LDM Localization 功能 #2800 (已关闭): Ford_SWER_0071_0006:APINFO0 should be set to zero in all reported status
- Even though APINFO0 is designated as unused, it should be set to zero in all reported status bytes
- 10:54 FORD LDM Localization 功能 #2798 (已关闭): Ford_SWER_0071_0005:APINFOx should follow Ford Standards
- Even though APINFO4 is called out by J2602, it is included in this list because Ford expects that all nodes continue ...
- 10:50 FORD LDM Localization 功能 #2797 (已关闭): Ford_SWER_0071_0004:All nodes are required to report Error Status
- All nodes are required to report the Ford Standard J2602 Error Handling Extension
o Ford Standard J2602 Error Handl... - 10:46 FORD LDM Localization 功能 #2796 (已关闭): Ford_SWER_0071_0003:Errors are reported once in LIN communicaition
- All these faults are "one-shot." In other words, they are only reported once and then they are cleared and not report...
- 10:37 FORD LDM Localization 功能 #2790 (已关闭): Ford_SWER_0071_0002:Error Status meanings in first byte for LIN communication
- |ERR2 |ERR1 |ERR0 |Meaning|
|0 |0 |0 |No fault detected|
|0 |0 |1 |Reset|
|0 |1 |0 |Reserved|
|0 |1 |1 |Reserved|... - 10:29 FORD LDM Localization 功能 #2785 (已关闭): Ford_SWER_0071_0001:Data format for first byte of LIN communication
- SAE J2602 Status Byte
In J2602, the first byte transmitted by any node is the LIN Status Byte. It has this format:
...
2024-10-28
- 14:10 FORD LDM Localization 功能 #2530 (进行中): Ford_SYSR:FS_REQ0010_V1 Channel 1 Failsafe Mode
2024-10-24
- 16:03 FORD LDM Localization 功能 #2520 (已关闭): Ford_SYSR: FS_REQ0001_V2 LDM Input
- The LDM will use Channel2 as main power input as HS REQ005, and rest channels input to be used as an input signal to ...
- 15:58 FORD LDM Localization 功能 #2519 (已关闭): Ford_SYSR: System Requirement
- -FS_LDM Localization_V2.0.docx-
FS_LDM Localization_V2.6.docx
HS_LDM Localization_V2.2.docx - 14:54 FORD LDM Localization Task #2516 (已关闭): Ford_SWET: Static code analysis
- Application software Static code analysis(S00071691.7)
2024-10-22
- 10:30 FORD LDM Localization Task #2510 (进行中): Ford_Fusa: function Safety SSR
- Complete and sign Fusa SSR documents with Ford team
- 10:28 FORD LDM Localization Task #2509 (已关闭): Ford_SWET: DV&PV Software Test
- Ford LDM Function Test
- 10:26 FORD LDM Localization Task #2508 (已关闭): Ford_SWED: DV&PV Software Release
- Release Software for DV/PV test:
Boot loader Software Version:SW0007170.B001
Application Software Version:SW0007169...