功能 #2519: Ford_SYSR: System Requirement

Ford_SYSR:FS_REQ0050_V2 LDM intermal Thermal Derating

玉洁 金大约一年 之前添加. 更新于 8 个月 之前.

状态:
已关闭
优先级:
普通
指派给:
开始日期:
2024-10-28
计划完成日期:
2024-11-07
% 完成:

100%

预期时间:
(合计: 0.00 小时)

描述

The LDM shall have an internal NTC thermistor and monitor temperatures critical to operation. To avoid stressing the LDM, the outputs shall be derated to increase efficiency. Derating shall occur by reduction of current output. The functional outputs shall be prioritized as follows:
Temperature Function Maximum Allowable Derating
125℃ Foreground LB 50%
HB 50%
Turn Indicator 50%
DRL/Park 50%
SBL 50%
135℃ Foreground LB 70%
HB 70%
Turn Indicator 50%
DRL/Park 50%
SBL 50%
145℃ Foreground LB 70%
HB 100%
Turn Indicator 50%
DRL/Park 50%
SBL Deactivated

Table 17: LDM Internal Thermal Derating Output Requirements

NOTE1: Temperature1/2/3 should refer to the LDM thermal simulation.

NOTE2: Derated functions shall recover to performance of the previous range with a 5°C hysteresis.
Example: If Temperature2 is reached and HB is at 50% output for thermal derating, the temperature reading of the NTC must drop to less than (Temperature2 – 5℃) before returning to 80% output and (Temperature1 – 5℃)for full performance.


子任务 6 (0 打开6 已关闭)

功能 #2742: Ford_SYER_0050_0001:LDM Internal Thermal Derating for Foreground LB已关闭云浩 汪2024-11-012024-11-07

行为
功能 #2743: Ford_SYER_0050_0002:LDM Internal Thermal Derating for HB已关闭云浩 汪2024-11-012024-11-07

行为
功能 #2744: Ford_SYER_0050_0003:LDM Internal Thermal Derating for Turn Indicator已关闭云浩 汪2024-11-012024-11-07

行为
功能 #2746: Ford_SYER_0050_0004:LDM Internal Thermal Derating for DRL/PL已关闭云浩 汪2024-11-012024-11-07

行为
功能 #2747: Ford_SYER_0050_0005:LDM Internal Thermal Derating for SBL已关闭槐 杨2024-10-282024-10-31

行为
功能 #2748: Ford_SYER_0050_0006:LDM Internal Thermal Derating Hysteresis已关闭云浩 汪2024-11-012024-11-07

行为
行为