Ford_SYSR:FS_REQ0006_V1 DRL/PO Power supply

玉洁 金8 个月 之前添加. 更新于 7 个月 之前.

状态:
已关闭
优先级:
普通
指派给:
开始日期:
2024-10-25
计划完成日期:
2024-11-07
% 完成:

100%

预期时间:
(合计: 0.00 小时)

描述

DRL/PO input can be supplied with two different modes:
1) a PWM signal from BCM direct wire ‘L/RF_DRL_LAMP_Ckt’ to provide information about DRL state.
2) a steady state power supply from Main power and activate DRL/PO with LIN command ‘DRL_Rqst’ from BCM For CD764ICA and CX483MCA,Channel 2 and 4 using a single fused connection to battery with relay. And the DRL/PO intensity is configured in LDM parameters setting and activate with LIN command.

For CDX706,Channel 2 using a single fused connection to battery with relay, Channel 4 is connected to BCM L/RF_DRL_LAMP_Ckt directly, and the hardwire will provide the PWM signal to determine DRL/PO intensity.


子任务 3 (0 打开3 已关闭)

功能 #2630: Ford_SWER_0006_0001: DRL/PO触发方式已关闭培源 左2024-10-252024-10-31

行为
功能 #2972: Ford_SWER_0006_0002: DRL/PO硬线触发方式已关闭平平 陈2024-11-012024-11-07

行为
功能 #2973: Ford_SWER_0006_0003: DRL/PO LIN触发方式已关闭平平 陈2024-11-012024-11-07