SAE J2602 Status Byte
In J2602, the very first byte transmitted by any node is the LIN Status Byte. It has this format:
LIN J2602 Status Byte
Bit 7 (MSB) Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 (LSB)
ERR2 ERR1 ERR0 APINFO4 APINFO3 APINFO2 APINFO1 APINFO0
ERR2 ERR1 ERR0 Meaning
0 0 0 No fault detected
0 0 1 Reset
0 1 0 Reserved
0 1 1 Reserved
1 0 0 Data (loopback) Error
1 0 1 Checksum Error
1 1 0 ByteField Framing Error
1 1 1 ID Parity Error

Table 36: LIN J2602 Status Byte Meanings (BITs ERR2, ERR1, ERR0)
All these faults are "one-shot." In other words, they are only reported once and then they are cleared and not reported again until they occur again.
o DLPL_LIN_15_002 – Ford Standard J2602 Extension

All nodes are required to report the Ford Standard J2602 Error Handling Extension
o Ford Standard J2602 Error Handling Extension

Even though APINFO4 is called out by J2602, it is included in this list because Ford expects that all nodes continue to report these errors as long as the error exists.

Even though APINFO0 is designated as unused, it should be set to zero in all reported status bytes

APINFO4 APINFO3 APINFO2 APINFO1 APINFO0 Meaning
0 0 0 0 unused No failure to report
1 Don't care Don't care Don't care unused Node not configured
Don't care 0 1 Don't care unused Output disabled temporarily due to environmental issue (temperature, voltage), no short. Do not use this for load shedding. Note that this case should be used when the disabling of the output is not due to a vehicle repairable fault. The service manual should indicate that the condition was due to the capacity of the output being exceeded.
Note: Currently the LDM does use or set this fault type.
Don't care 1 0 Don't care unused One or more outputs disabled temporarily due to short or open circuit. (Load Fault)
Don't care 1 1 Don't care unused ECU fault (can be any internal fault or an output driver fault)
Don't care Don't care Don't care 1 unused One or more input faults detected.Note that this is unreliable when the node reports ECU fault.

Note: ECU fault can be used to indicate other major faults besides output FET and 3/3 life.
Table 37: Ford Standard Extension of LIN J2602 Status Byte


子任务 7 (0 打开7 已关闭)

功能 #2785: Ford_SWER_0071_0001:Data format for first byte of LIN communication已关闭永琪 徐2024-10-292024-11-07

行为
功能 #2790: Ford_SWER_0071_0002:Error Status meanings in first byte for LIN communication已关闭涛 陆2024-10-292024-11-07

行为
功能 #2796: Ford_SWER_0071_0003:Errors are reported once in LIN communicaition已关闭涛 陆2024-10-292024-11-07

行为
功能 #2797: Ford_SWER_0071_0004:All nodes are required to report Error Status已关闭永琪 徐2024-10-292024-11-07

行为
功能 #2798: Ford_SWER_0071_0005:APINFOx should follow Ford Standards已关闭永琪 徐2024-10-292024-11-07

行为
功能 #2800: Ford_SWER_0071_0006:APINFO0 should be set to zero in all reported status已关闭永琪 徐2024-10-292024-11-07

行为
功能 #2811: Ford_SWER_0071_0007:APINFO0 bit map已关闭永琪 徐2024-10-292024-11-07

行为
行为

导出 Atom PDF