项目

一般

简介

行为

功能 #2591

打开

Ford_SYSR:FS_REQ0070_V2 BCM EEL VO Load Sequencing

玉洁 金8 个月 之前添加. 更新于 3 个月 之前.

状态:
新建
优先级:
普通
指派给:
开始日期:
2024-10-29
计划完成日期:
2025-03-31 (大约 3 个月 延期)
% 完成:

0%

预期时间:
(合计: 0.00 小时)

描述

The following command message is used to actuate each load individually. The LDM shall only consider LF EEL and RF EEL depending on the mounting location detected.
For writing requirements (Service 2F) please refer to 6.5.3.70 0x427E- Enhanced Exterior Lighting Load Sequencing Request Status in BCM FS.

o Name: VO_Load_Seq
o Size: 8 Bytes
o Type: Command frame
o Identifier: 0x07
o Sampling: 80 ms

Table 34: LIN VO Load Sequencing FRAME DEFINITION
The Vehicle Operation Load Sequencing command provides a methodology that allows individual lamp loads to be active via diagnostics command to the BCM. The tester will look for the change in load to verify operation and that all connections in the functional path are intact (nothing is left unplugged). The message consists of 5 bytes of data, 1 byte per Lighting Module. The high order bit will enable load switching for that Module. The lower order 7 bits will be tied to a single load each in software (Supplier Defined). All loads OFF will be 0x00. To turn an output ON, the high order bit is set to 1 along with the desired load bit. Because the intent is to operate one load at a time, when a Lighting Module is actively commanded to drive a load the other four Lighting Modules will be OFF (0x00). This message will be broadcast only upon a diagnostics command to the BCM; the BCM will execute a separately defined schedule table (With No Standard Functional messages) and will set the Modules into the Load Sequencing Test State. The Signal definition table in the next section illustrates the signals for one Lighting Module only (Extra LDM/FCM).

Table 35: LIN VO Load Sequencing Signal Definition
The LDM shall consider the following loads:
Load 0: Static Bending Light (All applicable light sources)
Load 1: LB
Load 2: HB
Load 3: TI
Load 4: DRL
Load 5: POS
Load 6: PWMx(All applicable Light Sources)


文件


子任务 3 (3 打开0 已关闭)

功能 #2835: Ford_SWER_0070_0001:VO_Load_Seq 0x07反馈盛炜 朱2024-10-292025-03-04

行为
功能 #2845: Ford_SWER_0070_0002:The Vehicle Operation Load Sequencing command and functional correspondence进行中盛炜 朱2024-10-292025-03-31

行为
功能 #2848: Ford_SWER_0070_0003:How the Vehicle Operation Load Sequencing command is applied进行中盛炜 朱2024-10-292025-03-31

行为
行为 #1

涛 陆 更新于 8 个月 之前

部分完成,PWM信号未接入

行为 #2

斌 徐 更新于 8 个月 之前

  • 目标版本H003_SW0007169.A001.8 变更为 H004_SW0007169.A002.0

TBD

行为 #3

斌 徐 更新于 7 个月 之前

  • 目标版本H004_SW0007169.A002.0 变更为 H005_SW0007169.A003.0
  • 父任务 已删除 (#2519)
行为 #4

涛 陆 更新于 4 个月 之前

  • 目标版本H005_SW0007169.A003.0 变更为 H005_SW0007169.A003.2

目标版本改为A003.2

行为 #5

槐 杨 更新于 3 个月 之前

  • 指派给槐 杨 变更为 永琪 徐

更新测试用例,完成测试

行为

导出 Atom PDF