Ford_SYSR:FS_REQ0026_V2 DRL Control Strategy

玉洁 金8 个月 之前添加. 更新于 2 个月 之前.

状态:
已关闭
优先级:
普通
指派给:
开始日期:
2024-10-29
计划完成日期:
2024-11-07
% 完成:

100%

预期时间:
(合计: 0.00 小时)

描述

The module will be capable of determining DRL state by either BCM LIN or by BCM ‘L/RF_DRL_LAMP_Ckt’ direct wire.

When direct wire control is used the parameter “DRL_POS_Trigger_DutyCycle_cfg” will trigger the DRL to go into lower intensity mode referred to position function when the direct wire duty cycle falls below the configured value. Values range between 10-41%, 200Hz.

If BCM DRL direct wire duty cycle >= “DRL_POS_TriggerDC_cfg”, it should be ‘DRL intensity’.
If BCM DRL direct wire duty cycle < “DRL_POS_TriggerDC_cfg”, it should be POS intensity, which is configured by parameter ‘ParkPos_Intensity_cfg’.

NOTE1: Set ‘DRL_POS_Trigger_DutyCycle_cfg’ significantly higher/lower than BCM DRL direct wire duty cycle value to avoid the sampling error. For example: If BCM DRL direct wire duty cycle of POS is 10%, ‘DRL_POS_Trigger_DutyCycle_cfg’ should be at least 15%.

NOTE2: POS duty cycle cannot be below 5%. Lower values will be ignored and 5% will be used instead.
NOTE3: “DRL_Intensity” should be 100% as default value.


子任务 4 (0 打开4 已关闭)

功能 #2858: Ford_SWER_0026_0001:DRL Control Mode for dataset已关闭培源 左2024-10-292024-10-31

行为
功能 #2865: Ford_SWER_0026_0002:DRL value for dataset已关闭培源 左2024-10-292024-10-31

行为
功能 #2998: Ford_SWER_0026_0003:DRL value for App已关闭云浩 汪2024-10-312024-11-07

行为
功能 #3007: Ford_SWER_0026_0004:DRL frequency已关闭云浩 汪2024-11-012024-11-07

行为
行为 #1

涛 陆 更新于 8 个月 之前

完成

行为 #2

玉洁 金 更新于 8 个月 之前

  • 描述 已更新。 (差异)
行为 #3

玉洁 金 更新于 8 个月 之前

  • 描述 已更新。 (差异)
行为 #4

斌 徐 更新于 7 个月 之前

  • 状态新建 变更为 已关闭
行为 #5

玉洁 金 更新于 2 个月 之前

  • 主题Ford_SYSR:FS_REQ0026_V1 DRL Control Strategy 变更为 Ford_SYSR:FS_REQ0026_V2 DRL Control Strategy

更改标题V1为V2

行为

导出 Atom PDF