描述
The input will be active in BCM failsafe mode, and only under DRL hardwire control condition, the DRL and all corresponding main functions of the DRL shall be operational only with “DRL Power supply Channel”(L/RF_DRL_Lamp_Ckt). Requirements for these specific functions will be described in following sections
| Function | Failsafe Requirement |
| DRL Light Output | Required |
| DRL Thermal Derating | Required |
| DRL Bin Sense | Required |
| Channel Open/Short Detection | Required |
| N-1 Failure Detection | Required (if enabled) |
| Active Load Fault Reporting via LIN | Required (if enabled) |
Table 9: DRL failsafe strategy