To enhance the LB fault handling capability under FUSA TSR 1.4.2 requirement, to adopt LB hardwire or LIN signal “Headlamo_Low_Beam_Out” as activate source and redundant design. Besides, LDM shall report the LB Outage while LB hardwire active status and LIN signal "Headlamp_Low_Beams_Out" ON status mismatch within 1000ms. 

 |LB 
 LB Hardwire ckt|Headlamp_Low_Beams_Out|LB Function|LB Outage| ckt 	 Headlamp_Low_Beams_Out 	 LB Function 	 LB Outage 
 |Active           |ON 	                |On           |No         | Active 	 ON 	 On 	 No 
 |Inactive         |ON 	                |On           |Yes        | Inactive 	 ON 	 On 	 Yes 
 |Inactive         |OFF 	                |Off 	    |No         | Inactive 	 OFF 	 Off 	 No 
 |Active           |OFF 	                |On 	    |Yes        | 
 Active 	 OFF 	 On 	 Yes 


 Table: LB hardwire and LIN signal mismatch 