项目

一般

简介

功能 #2565

玉洁 金 更新于 7 个月 之前


 The activation of FAN can be configured by the parameter ‘FAN_Activation_Trigger_cfg’. 
 • 	 0x00: No FAN 
 • 	 0x01:Activate upon Ignition On 
 • 	 0x02: Activate upon LB or HB is activated 
 • 	 0x03: Activate upon FAN NTC temperature is > ‘Fan_Activation_Temp_cfg’ 

 If ‘FAN_Activation_Trigger_cfg’ = 0x03 0x02 which means FAN will be activated when the temperature is more than the function threshold, ‘FAN_Activation_NTC_cfg’ and ‘Fan_Activation_Temp_cfg’ should be enabled to choose which NTC source and the temperature threshold should be used. If the temperature recover from a high temperature to low temperature, a 5℃ hysteresis should be applied. 

  

 ‘FAN_Activation_NTC_cfg’ definition: 
 • 	 0x00: NTC1 
 • 	 0x01: NTC2 
 • 	 0x02: NTC3 
 • 	 0x03: NTC4 

 ‘Fan_Activation_Temp_cfg’ definition: 
 • 	 Range: 50℃ to 100℃ 
 • 	 Resolution: 5℃ 

 If the FAN NTC is lost or out of range, Fan shall be activated if any lighting sources is activated. 

 