Under normal operating conditions, the LDM shall report Turn indicator status to the BCM by outputting the received signal from the BCM over the ‘L/RF_LED_Turn_Outage_Ckt’ line. The feedback must be stable 70ms after BCM output Turn on. The BCM does a 50 ms (max) debounce. The BCM makes the decision 120 ms (70 + 50) after Turn on.
TI outage detection report shall also occur via a hard wire back to BCM. Feedback signal will follow the “on/off” pattern matching the input signal from turn indicator input when no outage is detected. In case of outage Signal will remain “LOW” status the whole time.
• No Outage: Signal goes "HIGH” when TURN LEDs are activated.
• Outage: Signal remains "LOW" when TURN LEDs are activated.
• Outage: Signal remains continuous “High” when TI is activated and TI input short to Battery.
Note: BCM uses an active high input which has a 1.3K Ohm pull down resistor. The LDM module shall implement a high side driver with built-in short to ground protection circuit for outage feedback.
Following BCM TI outage feedback input max values to be considered:
Input Voltage Range: 8 – 19 V
Input Current Range: 0.007- 0.015 A
If no TI outage detected, the feedback should be equal or more than 8V(Shall consider to meet the requirement while 9-16V power supply);
If any TI outage detected, the feedback should be less than 2V.