The input will be active in BCM failsafe mode, and therefore the TI and all corresponding main functions of the TI shall be operational only with “TI Power supply Channel”(L/RF_Turn_Lamp_Ckt). Requirements for these specific functions will be described in following sections.
Below function in red may not achieved while only TI input available.
|Function |Failsafe Requirement|
|TI Light Output |Required|
| *TI |TI Thermal Derating* Derating | *Required* | |Required|
|TI Bin Sense |Required|
| *Channel |Channel Open/Short Detection* Detection | *Required* | |Required|
| *N-1 |N-1 Failure Detection* Detection | *Required |Required (if enabled)* | enabled)|
| *Active |Active Load Fault Reporting via LIN* LIN | *Required |Required (if enabled)* | enabled)|
| *TI Feedback* | *Required* | |TI Feedback |Required|
Table 8: TI failsafe strategy