2025-01-06
- 18:19 FORD LDM Localization Bug #3196 (Bug-不是问题): Ford_SWET_0017_0001_0002:LB 8.1V上电,下调电压,在7V就关闭了
- 18:17 FORD LDM Localization Bug #3188 (Bug-已关闭): DRL的NTC开路故障测试,电压低于9V时上电后做NTC短路故障,故障报警时长为316ms
- 18:16 FORD LDM Localization Bug #3189 (Bug-已关闭): DRL单颗短路故障,上电后做短路故障,故障报警时长为119ms
- 18:07 FORD LDM Localization Bug #3195 (Bug-已关闭): Ford_SWET_3.5_0070 电源电压低于9V,HB单颗LED开/短路故障
- 18:06 FORD LDM Localization Bug #3186 (Bug-已关闭): DRL的NTC短路故障测试,电压低于9V时上电后做NTC短路故障,故障报警时长为233ms
- 18:06 FORD LDM Localization Bug #3185 (Bug-已关闭): PL通道+短路故障测试,电源电压高于于16V时,上电后做通道短路故障,故障报警时长为190ms
- 18:05 FORD LDM Localization Bug #3184 (Bug-已关闭): PL通道+短路故障测试,电源电压低于9V时,上电后做通道短路故障,故障报警时长为286ms
- 18:04 FORD LDM Localization Bug #3183 (Bug-已关闭): NTC短路故障测试 --PL,低于9V时上电后做NTC短路故障报警时长为343ms
- 18:04 FORD LDM Localization Bug #3182 (Bug-已关闭): NTC超范围故障测试 --PL,上电前故障与上电后故障报警时长为1.5S
- 18:02 FORD LDM Localization Bug #3190 (Bug-已关闭): DRL单颗开路故障,电压高于16V时上电后做单颗LED开路故障,故障报警时长为1.19S
- 18:01 FORD LDM Localization Bug #3191 (Bug-已关闭): Ford_SWET_0001_0005_0002:软件低压降功率滤波时间太短,响应了400ms的电压变化
- 18:00 FORD LDM Localization Bug #3204 (Bug-已关闭): Ford_SWET_3.5_0068 HB单颗LED开路
- 17:58 FORD LDM Localization Bug #3282 (Bug-已关闭): 报警时间问题
- 目前发现系列问题:报警时间不准。
- 17:40 FORD LDM Localization Bug #3181 (Bug-问题解决): PWM/LSSS 故障联动测试
- 17:38 FORD LDM Localization Bug #3187 (Bug-问题回归验证): Ford_SWET_0038_0001_0101/102:DRL和PWM动画同时触发时,动画时长有误,DRL和DRL2亮灭时间不同步
- 17:33 FORD LDM Localization Bug #3281 (Bug-问题回归验证): dataset上DRL2配置异常
- 09:15 FORD LDM Localization Bug #3198 (Bug-问题回归验证): 只有不分温度迟滞符合要求,buck温度降功率恢复时电流波动过大
- 09:11 FORD LDM Localization Bug #3223 (Bug-问题回归验证): Ford_SWET_0028_0001_0006:配置DRL随LB_Outage切换成PL,打开LB,不管LB有没有故障,都会切换成PL。配置PL随LB_Outage关闭,不管点不点LB,PL都打不开
- 08:34 FORD LDM Localization Bug #3225 (Bug-问题回归验证): Ford_SWET_0029_0001_0015:PWM的配置上不能配超过60%,超过60就会点不亮;在60以下PWM情况下,灯可以亮 但是占空比实测下来不管配多少 都是1%左右
- 08:30 FORD LDM Localization Bug #2513 (Bug-问题回归验证): 单元测试测试问题反馈