- 20:09 FORD LDM Localization Bug #3190 (Bug-已关闭): DRL单颗开路故障,电压高于16V时上电后做单颗LED开路故障,故障报警时长为1.19S
- 测试ID:Ford_SWET_3.5_0136
配置:Channel2_usage_cfg=0x03
Channel3_usage_cfg=0x03
DRL_ Failure_Report_cfg=0x0... - 20:03 FORD LDM Localization Bug #3189 (Bug-已关闭): DRL单颗短路故障,上电后做短路故障,故障报警时长为119ms
- 测试ID:Ford_SWET_3.5_0140
配置:Channel2_usage_cfg=0x03
Channel3_usage_cfg=0x03
DRL_ Failure_Report_cfg=0x0... - 19:55 FORD LDM Localization Bug #3188 (Bug-已关闭): DRL的NTC开路故障测试,电压低于9V时上电后做NTC短路故障,故障报警时长为316ms
- 测试ID:Ford_SWET_3.5_0175
配置:Channel2_usage_cfg=0x03
Channel3_usage_cfg=0x03
DRL_Failure_Deact_cfg =0
... - 17:00 FORD LDM Localization Bug #3186 (Bug-已关闭): DRL的NTC短路故障测试,电压低于9V时上电后做NTC短路故障,故障报警时长为233ms
- 测试ID:Ford_SWET_3.5_0180
配置:Channel2_usage_cfg=0x03
Channel3_usage_cfg=0x03
DRL_ Failure_Report_cfg=0x0... - 16:39 FORD LDM Localization Bug #3185 (Bug-已关闭): PL通道+短路故障测试,电源电压高于于16V时,上电后做通道短路故障,故障报警时长为190ms
- 测试ID:Ford_SWET_3.5_0237
配置:Channel2_usage_cfg=0x03
Channel3_usage_cfg=0x03
DRL_ Failure_Report_cfg=0x0... - 16:21 FORD LDM Localization Bug #3184 (Bug-已关闭): PL通道+短路故障测试,电源电压低于9V时,上电后做通道短路故障,故障报警时长为286ms
- 测试ID:Ford_SWET_3.5_0236
配置:Channel2_usage_cfg=0x03
Channel3_usage_cfg=0x03
DRL_ Failure_Report_cfg=0x0... - 15:21 FORD LDM Localization Bug #3183 (Bug-已关闭): NTC短路故障测试 --PL,低于9V时上电后做NTC短路故障报警时长为343ms
- 测试ID:Ford_SWET_3.5_0246
配置:DRL_ Failure_Report_cfg=0x01 ;FAN_Activation_NTC_cfg =3 ;FAN_Activation_Temp_cfg =50°-100... - 15:07 FORD LDM Localization Bug #3182 (Bug-已关闭): NTC超范围故障测试 --PL,上电前故障与上电后故障报警时长为1.5S
- 测试ID :Ford_SWET_3.5_0250
配置:DRL_ Failure_Report_cfg=0x01 ;FAN_Activation_NTC_cfg =3 ;FAN_Activation_Temp_cfg =50°-10...
2024-11-29
- 09:14 FORD LDM Localization Bug #3149 (Bug-不是问题): DRL的NTC开路一侧通道不降功率
- 重新配置dataset后,再制造NTC2开路,通道3的电流由498ma降至206ma
2024-11-28
- 15:31 FORD LDM Localization Bug #3149 (Bug-已关闭): DRL的NTC开路一侧通道不降功率
- 测试ID:Ford_SWET_3.5_0174
配置:DRL_ Failure_Report_cfg=0x01
"FAN_Activation_NTC_cfg" =3
"FAN_Activation_Te...
2024-11-27
- 09:30 FORD LDM Localization Bug #3082: 转向闪烁情况下,多次断上电,有概率近光灯异常打开
- 按操作步骤复现半小时,未复现故障