帅辉 罗 的活动
从 2024-11-05 到 2024-11-14
2024-11-14
- 19:49 FORD LDM Localization Bug #3070 (Bug-已关闭): Ford_SWET_3.5_306
- 19:47 FORD LDM Localization Bug #3047 (Bug-已关闭): TURN配置为无故障联动,实测仍然有故障联动
- 00:07 FORD LDM Localization Bug #3073 (Bug-已关闭): Ford_SWET_3.5_317
- 当TURN NTC超范围(过低)时,LDM需要按照NTC最低降功率值输出,实测未降功率
- 00:05 FORD LDM Localization Bug #3072 (Bug-已关闭): Ford_SWET_3.5_316
- 当TURN NTC
超范围(过高)时,要强制风扇运行.实测风扇不运行
当TURN NTC
超范围(过高)时,TURN需要按照NTC最低降功率值输出,实测未降功率
2024-11-13
- 23:47 FORD LDM Localization Bug #3071 (Bug-已关闭): Ford_SWET_3.5_311
- 配置NTC短路后,要强制风扇运行.实测风扇不运行
当TURN,LB,HB,DRL,PL NTC电阻短路时,LDM需要按照NTC最低降功率值输出,实测未降功率 - 23:44 FORD LDM Localization Bug #3070 (Bug-已关闭): Ford_SWET_3.5_306
- 配置TI_ Failure_Report_cfg=0x01
,"FAN_Activation_NTC_cfg" =3
"FAN_Activation_Temp_cfg" =50°-100°,
NTC开路后,要强制风扇运行.实测... - 23:18 FORD LDM Localization Bug #3069 (Bug-已关闭): TURN RBIN故障反馈时间为0ms
- TURN RBIN故障反馈时间为0ms
- 15:59 FORD LDM Localization Bug #3053 (Bug-已关闭): TURN_Failure_Deact_cfg =disable时, TURN单颗开路,硬线outage报警,LIN线不报警 ;TURN单颗短路,硬线outage不报警,LIN线报警
- TURN_Failure_Deact_cfg =disable时,
TURN单颗开路,硬线outage报警,LIN线不报警
TURN单颗短路,硬线outage不报警,LIN线报警 - 14:52 FORD LDM Localization Bug #3051: 有故障联动,TURN单颗 短路,硬线 outage 未报警
- 有故障联动,TURN单颗 短路,硬线 outage 未报警
- 14:45 FORD LDM Localization Bug #3051 (Bug-已关闭): 有故障联动,TURN单颗 短路,硬线 outage 未报警
- 无故障联动,TURN单颗 短路,硬线 outage 未报警
- 10:15 FORD LDM Localization Bug #3047 (Bug-已关闭): TURN配置为无故障联动,实测仍然有故障联动
- TURN配置为无故障联动,实测开路故障时仍然有故障联动
导出 Atom