15:53 FORD LDM Localization 功能 #2903 (已关闭): Ford_SWER_0025_0006:Feedback output Voltage for No Outage&Outage
If no TI outage detected, the feedback should be equal or more than 8V(Shall consider to meet the requirement while 9... 娟 高
15:50 FORD LDM Localization 功能 #2902 (已关闭): Ford_SWER_0025_0005:Outage Feedback Input Max Values
Following BCM TI outage feedback input max values to be considered:
Input Voltage Range: 8 – 19 V
Input Current Ra...
娟 高
15:48 FORD LDM Localization 功能 #2901 (已关闭): Ford_SWER_0025_0004:Outage feedback conditions for resistor and circuit
Note: BCM uses an active high input which has a 1.3K Ohm pull down resistor. The LDM module shall implement a high si... 娟 高
15:44 FORD LDM Localization 功能 #2900 (已关闭): Ford_SWER_0025_0003:Turn Indicator Feedback signal for No Outage&Outage
TI outage detection report shall also occur via a hard wire back to BCM. Feedback signal will follow the “on/off” pat... 娟 高
15:36 FORD LDM Localization 功能 #2899 (已关闭): Ford_SWER_0025_0002:Turn Indicator Feedback time
The software must be stable 60ms after BCM output Turn on. 娟 高
15:26 FORD LDM Localization 功能 #2898 (已关闭): Ford_SWER_0025_0001:Turn Indicator Status Feedback Method
Under normal operating conditions, the LDM shall report Turn indicator status to the BCM by outputting the received ... 娟 高
 